Model
CACG10KW
CACG30KW
Rating
34.120 BTU
(10 kW)
102,360BTU
(30kw)
Fuel Consumption
0,73 kg/h
2.18kg/h
Fuel Orifice Port Size
0,74 mm
1.28mm
Air Flow Temp.
420
℃
430
℃
Type gas
For use with PROPANE only
Type Of Gas
700 mbar
700 mbar
Gas Supply Pressure
220-240V~ 50Hz
Electricity Input
PIEZO
Ignition
Thermal Probe Operated Gas Valve
Primary Flame Control
95
℃
75
℃
WARNINGS
your safety is important to you and to others, so please read these instructions
before you operate this heater.
GENERAL HAZARD WARNING:
failure to comply with the precautions and instructions provided with heater,
can result in death, serious bodily injury and property loss or damage from
hazards of fire, explosion, burn, asphyxiation, carbon monxide poisoning,
and/or electrical shock.
only persons who can understand and follow the instructions should use or
service this heater.
not for home or recreational vehicle use.
●
Use only in a well ventilated area and away from combustible materials
●
NOT to be used for the heating of habitable .areas of domestic premises,for use in
. Public buildings,refer to national regulations .
●
After use turn off the gas supply at the cylinder valve.
●
Ensure that the fan is operating correctly before lighting the burners.
●
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and