DO
carefully read this installation manual before commencing installation.
DO
ensure the floor surface is smooth, clean and dry before priming the floor with
Warmup
®
primer.
DO
ensure good ventilation during application and drying of the primer.
DO
lay the wires whilst the primer is still “tacky” to ensure the greatest level of adhesion.
DO
plan the heater layout and installation so that any drilling after tiling (e.g. for fixing
sanitary ware) will not damage the wiring.
DO
maintain a gap between heating wire runs of at least 50mm (2 inches) at all times.
DO
make sure that ALL heating wire, including joints, are positioned under the tiles in the
installation.
DO
protect the heating wire with cardboard or hardboard between installation and tiling.
DO
use ceramic tile adhesives and grouts suitable for use with underfloor heating.
DO
check that the heater is working immediately before commencing tiling.
DO
take particular care when tiling not to dislodge or damage the heating wire.
DO
ensure that each tile is solidly bedded in tile adhesive, with no gaps or voids beneath.
DO
ensure that the heating elements are installed at least 50mm from conductive parts
of the building, such as water pipes.
DON’T
install the Warmup
®
Undertile Heating System heater under any floor other than
ceramic, quarry or natural stone tiles.
DON’T
commence installation on a concrete floor that has not been fully dried.
DON’T
allow traffic over the primed floor or the installed heating wire before tiling.
DON’T
cut or shorten the heating wire at any time.
DON’T
allow the heating wires to cross over or touch each other at any point.
DON’T
store tiles, sharp or heavy objects on any of the wiring whilst tiling.
DON’T
commence tiling before testing the Warmup
®
Undertile Heating System.
DON’T
switch on the installed heating system until tile adhesive has fully dried (7 days
minimum).
DON’T
install the heating wire on stairways or up the walls.
DON’T
install the mat in temperatures less than +5°C.
DON’T
bend the heating cable under a 25mm radius.
The heating must be separated from other heat sources such as luminaires and chimneys.
WARNING
During the course of the installation care must be taken to ensure that no damage is caused by, for
example, falling objects, sharp objects, walking on the heating element. Once the heating wire has been
installed avoid all traffic over the wire until the floor has been tiled and the adhesive has set. Do not install
the heating wire until the floor is ready to be tiled. If the floor is not being tiled immediately, all heating
wires must be protected with two layers of cardboard or hardboard to prevent damage. Immediately prior
to tiling, test the heating wires as specified on page 14 to check it has not been damaged. If you are in
any doubt call the Warmup
®
Undertile Heating helpline on
0845 345 2288.