When installing two or more heaters, begin by reading the sizing guide at the back of this
booklet to ensure that you have the proper number and size of heaters for the area you
wish to heat. The sizing guide will also tell you the perimeter and heating wire spacing
required for your particular room size.
After you have primed the subfloor, mark the subfloor as per the instructions on page 11
and lay the first heater. Do not cover the first heater with tape at this point as you may wish
to slightly alter the spacings later on.
Lay the second heater in the remaining area using the same perimeter and heating wire
spacings as the first heater. Please note that all heaters will start in the same area next to
the Warmup
®
Thermostat location.
When laying more than one heater, it is important to keep these points in mind:
1
The heating wires may not touch or cross at any point.
2
The heaters are joined in parallel only at the Thermostat or in a junction box.
Do not attach one heater to another in series.
3
The heating wire spacings for all heaters in an area should be approximately equal.