WARRANTY -

 

ROOF & GUTTER DE-ICING CABLES

Warmup provides a 10-Year Warranty (from date of purchase) for the Snow Melting Mats and Cables for the material and 
workmanship under normal operating conditions. 

In case of defective material, Warmup’s obligation will be limited to the repair or supply of new material, free of charge to 
the customer. 

The Warranty does NOT cover installations made by unqualified personal or faults caused by incorrect design by others; misuse; 
damage caused by others; damage in transit; incorrect installation and any other subsequent damage that may occur. Cost 
related to repair/replacement will be fully chargeable to the customer if the damage is due to any of the above reasons. 

Warmup is under no circumstances liable for consequential damages or losses including without limitations the loss or profit 
arising from any cause whatsoever. The guarantee is a material warranty only and does NOT cover field labor. 
A qualified electrician MUST connect the heating system. 

The Warranty is void if there is any payment default and if data is not filled in correctly. 

EXCLUSIONS

 

Warmup, Inc. shall in no event be liable for incidental or consequential damages, including but not limited to extra utility 
expenses or damages to property. This Warranty is null and void if:
1) The covering over the heater(s) is damaged, lifted, replaced, drilled into or repaired. 
2) The heater fails due to damage caused during installation, unless damage is caused directly by an employee of Warmup. It 
is therefore essential to check that the heater is working (as specified in the installation manual) prior and during installation. 
3) Damage as a result of floods, fires, winds, lightning, accidents, corrosive atmosphere or other conditions beyond the control 
of Warmup, Inc. 
4) Use of components or accessories is not compatible with Warmup heaters. 
5) Warmup products are installed outside the United States. 
6) Parts not supplied or designated by Warmup, Inc. 
7) Damage or repair required as a result of any improper use, maintenance, operation or servicing. 
8) Failure to start due to interruption and/or inadequate electrical service. 
9) Any damage caused by frozen or broken pipes in the event of equipment failure. 
10) Changes in the appearance of the product that does not affect its performance. 
11) The owner, or his/her designated representative, attempts to repair the product without receiving prior authorization from 
Warmup. Upon notification of a repair problem, Warmup, Inc. will issue an Authorization to Proceed under the terms of this
Warranty. If Warmup is required to inspect or repair any defects caused by any exclusions referenced above, all work will be
fully chargeable at Warmup’s inspection and repair rates then in effect.

WARMUP, INC. DISCLAIMS ANY WARRANTY NOT PROVIDED HEREIN, INCLUDED ANY IMPLIED WARRANTY OF THE MERCHANTABLE 
OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. WARMUP, INC. FURTHER DISCLAIMS ANY RESPONSIBILITY FOR 
SPECIAL, INDIRECT, SECONDARY, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING FROM OWNERSHIP OR USE OF THIS PRODUCT, 
INCLUDING INCONVENIENCE OR LOSS OF USE. THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE FACE OF THIS DOCUMENT. 
NO AGENT OR REPRESENTATIVE OF WARMUP, INC. HAS ANY AUTHORITY TO EXTEND OR MODIFY THIS WARRANTY UNLESS SUCH 
EXTENSION OR MODIFICATION IS MADE IN WRITING BY A CORPORATE OFFICER. 
DUE TO DIFFERENCES IN BUILDING AND FLOOR INSULATION, CLIMATE AND FLOOR COVERINGS, WARMUP, INC. MAKES NO 
REPRESENTATION THAT THE FLOOR TEMPERATURE WILL ACHIEVE ANY PARTICULAR TEMPERATURE OR TEMPERATURE RISE. UL 
STANDARD LISTING REQUIREMENTS LIMIT THE HEAT OUTPUT OF WARMUP UNDERTILE HEATING, AS SUCH, USERS MAY OR MAY NOT 
BE SATISFIED WITH THE FLOOR WARMTH THAT IS PRODUCED. WARMUP DOES WARRANT THAT ALL HEATERS WILL PRODUCE THE RATED 
WATT OUTPUT LISTED ON THE HEATER NAMEPLATE, WHEN OPERATED AT THE RATED VOLTAGE. 

TERMS AND CONDITIONS 

Shipping Discrepancies: 
Incoming materials should be inventoried for completeness and for possible shipping damage. Any visible damages or 
shortages must be noted prior to accepting the material. Any discrepancy concerning type or quantity of material shipped, 
must be brought to the attention of your Warmup® reseller within 15 days of the shipping date entered on the packing slip 
for the order. 

Miscellaneous: 
The terms of this Limited Warranty are exclusive and supersede any other warranty or terms and conditions relating to the 
subject matter whether included in a purchase order for this product or in any other document or statement. 

10

Summary of Contents for NAMSR-5W-120

Page 1: ...RTANT Read this manual before attempting to install your heating system Incorrect installation could damage the heating system and will invalidate your warranty Installation Manual Cable for Roof Gutter De icing The world s best selling electric floor heating brand ...

Page 2: ...3 After removing the cable from the carton or wrapping check the insulation resistance of the unit from buss wires to braid with a 2500VDC megger to assure the cables have not been damaged during shipping and handling ELECTRIC SHOCK HAZARD Verify insulation resistance is 20 megohms or greater before installing Contact Warmup if cable is less than 20 megohm SIZING GUIDE Service voltage 110 120V 220...

Page 3: ...ircuit conductor and the rating or setting of overcurrent devices shall not be less than 125 of the ampere load of the cable or units WARNING ELECTRIC SHOCK HAZARD Disconnect all power before installing or servicing heating cable and accessories A qualified person must perform installation and service of heating cable and accessories Heating cable must be effectively grounded in accordance with th...

Page 4: ...oped in the downspout if it is convenient to do so such as when a downspout is not at the end of a run Note Tee splices are not permitted and void agency approvals E Use a Warmup downspout hanger to protect the heating cable from damage caused by sharp gutter edges and to provide strain relief F Protect any heating cable which protrudes past the lower opening of the downspout 4 Installing the inst...

Page 5: ...r problem areas and does not need to be installed on all areas of the roof In some instances on high pitched roofs over 40 degree slope and on roofs with minimal overhang no cable on the actual roof line may be required However always ensure to create a path for the ice to melt from the roof to the ground placing cable on the roof in the gutters and in the downspouts as necessary Extend the cable ...

Page 6: ...rmup s 24 7 Toll Free Technical Number US 1 888 927 6333 CAN 1 888 592 7687 PLANNING YOUR LAYOUT Draw a plan showing the layout and location of the snow melting cables below and keep it for future reference ...

Page 7: ...e Figure 3 FIGURE 2 Triangle pattern along the roof line FIGURE 1 Typical pattern along roof line and in gutters downspouts Pattern for the roof line The cable laid along the roof line is arranged in a triangular pattern see Figure 2 The cable MUST extend above the overhang into the heated section of the roof To determine the height of the triangles measure the depth of the overhang The triangle h...

Page 8: ...could also use a tape to measure each section of the downspout To calculate the total cable needed add the measurements in each section and multiply by 2 Lastly if it is not possible to use either of these above methods you may use the cable itself to estimate the length of cable needed in the downspout However to avoid snagging or cutting the cable on sharp edges take care when pulling the cable ...

Page 9: ...M POWER KIT Power Connection Kit for Self Regulating Cable Includes 2 warning labels ROOF CLIP Roof Clips Sold 50 pkg NAM SPLICE KIT Splice Tee Kit for Self Regulating Cable NAM END KIT End Seal Kit for Self Regulating Cable ASE DS8 Automatic controller with built in moisture sensor and 30A relay TRF 115 007 Line Voltage Controller 120 227V NEMA 4x enclosure with remote temperature sensor CDP 2 In...

Page 10: ...r broken pipes in the event of equipment failure 10 Changes in the appearance of the product that does not affect its performance 11 The owner or his her designated representative attempts to repair the product without receiving prior authorization from Warmup Upon notification of a repair problem Warmup Inc will issue an Authorization to Proceed under the terms of this Warranty If Warmup is requi...

Page 11: ... Danbury CT 06810 Tel 1 888 927 6333 Fax 1 888 927 4721 E mail us warmup com Web www warmup com CANADA Warmup Inc 374 Wellington St W Toronto ON M5V 1E3 Tel 1 888 592 7687 Fax 905 366 7324 E mail ca warmup com Web www warmup ca International Flooring Center Inc 5047 W Jefferson Blvd Los Angeles CA 90016 Tel 323 731 8453 www FlooringSupplyShop com ...

Reviews: