n
Remove the screw
holding the control
module to the
power base.
The screw cannot be
completely removed.
o
If you have a wall plate
:
Before making the connections,
make sure that the base covers the
electrical box entirely. Otherwise,
install the cover plate behind the
base.
NOTE:
The cover plate can also be used
to cover the plate for aesthetic reason.
p
Connect the wires:
•
Power
: Terminals 1 and 5
•
Load
: Terminals 2 and 4
•
Floor sensor
: Terminals 6 and 7 (no polarity)
• Terminal 3 (F.P.) is not connected
NOTE:
The terminals are designed to handle wires between 0.33
and 4 mm
2
.
The floor sensor must be centered between the heater wires
(80°C max.). Do not place the floor sensor next to a heater wire.
The temperature sensor wire must not cross any heater wires.
Make sure the temperature sensor wire is properly affixed along the
wall, in the concrete and into the electrical box (insulated material
only and could be run in a raceway) and that there is no interference
with the thermostat.
r
Push the wires into the electri-
cal box and secure the base to
the electrical box anchorage
using the screws provided.
s
Install the control module
onto the power base
(see owner’s guide)
.
t
Return power to the heating system.
Material
n
One (1) PB130-230 power base
o
One (1) wall plate
p
One (1) floor sensor
q
Two (2) screws
PB130-230
Power Base
Installation Instructions
Technical Specifications
Supply
: 230 VAC, 50 Hz
Maximum load
: 3450 Watts (NI) @ 230 VAC; 15 A (resistive only)
Compliance
: EN60730-2-9 / EN50081-1 / EN50082-2
Storage
: -20°C to 50°C (-4°F to 122°F)
Protection
: Class 2
Protection degree
: IP20
Automatic action
: Type 1.B
Environment
: Normally polluted
Size (H • W • D)
: 2.94 x 2.94 x 0.53 in. (74.6 x 74.6 x 13.3 mm)
Warranty
WARMUP PLC THREE-YEAR LIMITED WARRANTY
This product is warranted against material defects and workmanship in
normal use for a period of three (3) years, from the date of the original
purchase from authorized dealers. During this period,Warmup plc will
repair or replace the product with a new or of equivalent quality at Warmup
plc’s option, without charge, any product proven defective in normal use.
Warranty does not cover transportation costs. Nor does it cover a product
subjected to misuse or accidental damage. This warranty does not cover
the cost of installation, removal or reinstallation.
This limited warranty is in lieu of all other warranties, obligations or
liabilities expressed or implied by the company. In no event shall Warmup
plc be liable for consequential or incidental damages resulting from
installation of this product. This warranty does not affect your statutory
rights.
The defective product and the original sale receipt must be returned to the
original dealer or shipped pre-paid, insured and addressed to:
Warmup PLC
702 Tudor Estate
Abbey Road
London NW10 7UW
WEEE Directive:
•
Do not dispose along with
normal household waste.
•
Do not burn.
The product and its packaging must be
disposed at a suitable recycling centre.
Introduction
The PB130-230 power base is designed to power a TSTAT control
module. The resistive load must not exceed 3450 watts (NI) @
230 VAC (15 A).
Installation Guidelines
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.
Installation must be carried out by an electrician.
All work must conform to the most recent IEE regulations for
electrical installations and wiring.
This thermostat must be connected on a circuit equipped with
an RCD. It must be installed on a certified electrical box.
The thermostat must be installed on an inside wall.
1/3
400-608-000-C
Installation and Wiring