The preprogrammed schedule is used with the Automatic
mode and controls the floor temperature by automatically
alternating between the Comfort and Economy programs.
The schedule consists of 4 daily programs which are
defined as follows:
Program 1: time you wake up, Comfort temperature
Program 2: time you leave home, Economy temperature
Program 3: time you return home, Comfort temperature
Program 4: night time, Economy temperature
Overview of the preprogrammed schedule:
To modify the pre-programmed schedule, follow these
steps:
n
Press PGM; the first program
is displayed and the clock
segment flashes.
o
Use
to set the start time
of the first program.
p
Once you are done, repeat steps 1 and 2 for remain-
ing programs (2, 3 & 4).
q
Press MODE to exit.
Note: To modify the number of programs per day, see
“Advanced Programming”.
Note: After 60 seconds of inactivity, the thermostat will
automatically exit programming mode.
n
Press and hold PGM for 3 seconds to access the
advanced programming mode.
o
Press PGM to select the desired menu.
p
To modify the default programming, use
to
select an option.
q
Press MODE to exit.
Display Settings (unit)
°C/24h or °F/12h
To select the temperature and time display
format on the screen. PIA control mode.
P (Power Regulator)
In this mode, there is no temperature
reading nor display. Should be used only when the floor
sensor is damaged (E1/E2 error).
The TSTAT operates on perpetual heating cycles and
heating commands are sent based on the amount of
power you define.
For example (15-minute
a
cycle):
If you select 6 (60%) as the setpoint,
your system will heat for 60% of the
cycle; it will be ON for 9 minutes then
OFF for the last 6 minutes. Scale: 0 to 10 (0 to 100%).
Note: The time, day and programs are saved.
Programs
MO
TU
WE
TH
FR
SA
SU
1
6:00
6:00
2
8:30
3
17:00
4
23:00
23:00
PPD
1
1. Number of programs per day. See “Advanced Programming”.
4
4
4
4
4
2
2
Preprogrammed Schedule
Modify the Schedule
Description
Menu Default
Option
Display settings &
Temperature control
unit
°C/24h
°C/24h or
°F/12h
or P
Number of
programs per day
PPd MO
4
0, 2, 4
PPd TU
4
0, 2, 4
PPd WE
4
0, 2, 4
PPd TH
4
0, 2, 4
PPd FR
4
0, 2, 4
PPd SA
2
0, 2, 4
PPd SU
2
0, 2, 4
Heating Cycles
CPH
4
2, 3, 4, 5, 6
Advanced Programming
a. This thermostat has selectable heating cycles, see Heating Cycles below.
Setpoint and
equivalent %
1
0%
2
20%
4
40%
6
60%
8
80%
10
100%
ON
0 min
3 min
6 min
9 min 12 min 15 min
OFF
15 min 12 min 9 min
6 min
3 min
0 min
Number of Programs per Day
(PPd)
You can select the number of
programs to be executed for each
day of the week. For example, you can run all 4 programs
or only 2 (1st and 4th) or none (0).
Note: When none (0) is selected, the TSTAT will maintain
the temperature setpoint of the last program.
Heating Cycles (CPH)
You can select the number of
cycles per hour to suit your heating
area.
To minimize temperature swings, a large floor area
requires longer heating cycles, whereas a small floor
heating area requires shorter heating cycles.
Technical Specifications
Model
: TSTAT
Storage temperature
: -20°C to 50°C (-4°F to 122°F)
Software and controller
: Class A, electronic
Programming protection
: Protected memory
Clock protection
: 6 hours
Size (H/W/D)
: 3.2 x 3.3 x 0.65 in (81.4 x 84.6 x 16.5 mm)
Warranty
WARMUP PLC THREE-YEAR LIMITED WARRANTY
This product is warranted against material defects and
workmanship in normal use for a period of three (3) years, from
the date of the original purchase from authorized dealers. During
this period,Warmup plc will repair or replace the product with a
new or of equivalent quality at Warmup plc’s option, without
charge, any product proven defective in normal use.
Warranty does not cover transportation costs. Nor does it cover a
product subjected to misuse or accidental damage. This warranty
does not cover the cost of installation, removal or reinstallation.
This limited warranty is in lieu of all other warranties, obligations
or liabilities expressed or implied by the company. In no event
shall Warmup plc be liable for consequential or incidental
damages resulting from installation of this product. This warranty
does not affect your statutory rights.
The defective product and the original sale receipt must be
returned to the original dealer or shipped pre-paid, insured and
addressed to:
Warmup PLC
702 Tudor Estate
Abbey Road
London NW10 7UW
Cycles/hour
Length
2
30 min.
3
20 min.
4
15 min.
5
12 min.
6
10 min.
PIA temperature
control
Regulator
Pre-programmed
setpoints
28°C (82°F)
6 (60%)
20°C (68°F)
3 (30%)
Setting range
5°C to 40°C
(40°F to 104°F)
0 to 10
(0 to 100%)
Setting scale
0.5°
1 (10%)
Display range
-10°C to 60°C
(14°F to 140°F)
0 to 10
(0 to 100%)
Display scale
0.1°
1 (10%)
Temp. accuracy
± 0.2°C (0.36°F)
WEEE Directive:
•
Do not dispose along with
normal household waste.
•
Do not burn.
The product and its packaging must be
disposed at a suitable recycling centre.
10/11/2005
3/3
400-608-000-C