Application
The Frost Protection heating cable is designed for heating PVC or metal water pipes down to
-20°C at 230VAC according to protection class 1.
The thermistor ensures that the supply of electrical energy is reduced to the minimum
amount required. For protection against frost ,the thermistor will not switch on the heating
cable until the ambient temperature falls below 5°C.
A relatively large switching band ensures that entire pipe warms up so that the supply
will only be interrupted when the temperature exceeds 15°C. This reduces the amount of
switching on and off, allowing the thermistor to operate without any trouble over a long
period of time.
Technical Data
Range Specification
Model
Length
Total Wattage
Total Amperage (A)
Total Resistance (Ω)
W10FP20
2
20
0.09
2645.0
W10FP40
4
40
0.17
1322.5
W10FP60
6
60
0.26
881.7
W10FP80
8
80
0.35
61.3
W10FP100
10
100
0.43
529.0
W10FP150
15
150
0.65
352.7
W10FP200
20
200
0.87
264.5
Rated Voltage
230VAC
Outer Diameter
6.3 x 4.4 mm
Minimum Bending Radius
25mm
Resistance Tolerance
-5% / +10%
Operating Temperature
70°C
Cold Connection Cable
2m with Schuko plug
Min Installation Temperature
5°C
Temperature Regulator
+5°C on / + 15°C off
Protection Class
IPX7
Max. Surface output
10 W/m
Inner insulation
Fluoropolymer (FP)
Outer sheath insulation
Polyolefin; UV Resistant
DECLARATION OF CONFORMITY
This appliance conforms to the stipulations of the following IEC guidelines: IEC 60800:2009
Twin Conductors
Insulation
Coated Copper Braiding
Sheathing