84856A0
Figure 21 Red Wire - Tie-off 25cm (10in)
Red Wire
Secure a distance of 25cm
(10in) from this point
Secure with
Electrical Tape
e. Position the contactor with the post for the positive
battery cable (red cable) in the lower left corner
(leads for the handlebar switch are positioned
up), figure 19 & 20. Mark and drill 1/4” holes for
contactor. Secure the contactor with four 1/4-20 x
1” bolts, washers, lock-washers and nuts supplied
with the winch. Tighten the nuts to a recommended
torque of 7 N-m (5 ft-lb).
2. Handlebar Switch Installation - Step Four in the
Installation and Specification Guide:
a. Before installing the winch switch, route the red wire
towards the switch case. Secure with electrical tape
a distance of approximately 25cm (10in) from where
the red wire protrudes from the back casing towards
the switch case, figure 21. This will allow you to see
the red wire when routing the switch wires, down the
steering column, to the contactor.
Notice
Please note that all wires in the wiring
photographs are shown without conduit on
the colored wires. This is for clarity in the
instructions.
Figure 19 Contactor Location - Right Side of Tool Box
Red Cable
Figure 20 Contactor Location - Right Side of Tool Box
Switch Leads
Red Cable