987606A1.doc
Page 18 of 46
2.4.3 INSPECTION OF MOTOR
•
Visual inspection.
•
Ensure that Motor has been properly placed inside the End Housing and the screw had
been properly tightened
2.5 WIRE ROPE ASSEMBLY
2.5.1 REMOVAL OF WIRE ROPE
Note:
Prior to disassembly
:
1.
Spool out all Wire Rope.
2.
Use of gloves is recommended while handling frayed or damaged Wire Rope.
3. Unplug unit / remove Battery before disassembly.
Tasks:
Disassemble the Wire Rope.
1.
Push the Wire in the direction of the
arrow mark as shown in the figure.