Warner Electric • 800-825-9050
P-273-4-WE • 819-0528
5
Installing the Motor Mount Bracket
A Motor Mount Bracket can be installed on the
output end of a 1020 and 1040 UniModule to
provide a foot mounting for the complete assembly
of a UniModule and C-face motor.
Optional Motor Mount Kit,
Warner Electric part numbers:
UM-50/100............................5370-101-078
UM-180.................................5370-101-079
1. Mount the bracket to the face of the UniModule
underneath the UniModule and motor as shown in
Figure 5. A pilot diameter on the UniModule mates
with a pilot diameter on the bracket.
Figure 5
2. Secure the motor bracket in place with four (4)
short bolts and washers provided. Tighten to 18
to 22 foot pounds.
Mounting to Other Power
Transmission Components
Couplings, pulleys, sprockets or similar power
transmission components can be mounted to the
input and output shafts of a UniModule.
When mounting a pulley or
sprocket, ensure that the key is fully engaged
within the device hub or bushing.
Confirm that the belt or chain
tightness meets the maximum side load
capability of the UniModule shown in Table 2.
Overhung Load Data
(Shaft Side Load)
Overhung load data is provided in this manual for the
design engineer concerned with a specific problem
in this area. The maximum allowable overhung load
which can be applied to the shaft of an UniModule
may be determined by the use of the accompanying
chart.
Table 2
A
R
Distance Load is Applied from
Maximum
UniModule
Housing Face
Load Rating
“A” Inches
“R” Lbs.
UM-50
1” (Center of Shaft)
177
2” (End of Shaft)
123
3”
95
UM-100
1” (Center of Shaft)
192
2” (End of Shaft)
134
3”
104
UM-180
1” (Center of Shaft)
192
2” (End of Shaft)
134
3”
104