background image

 

  

Tension control system X2DRV 

29/08/2012 

 

X2DRV

 

Installation & Operation Manual

  

Page 4 of 5 

 

 

5.

 

Wire Controller or PLC (0-10V or 4-20mA Input) to pin InBK1 or InBK2 as shown figure  

 

6.

 

Set the Anti-residual with the white screw as shown figure 4 as describe below: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.

 

(Optional): Pins ON1, OFF1, ON2, OFF2 are NPN type Input: 

-

 

When ON (1 or 2) is set to Ground  =>  24V is applied on BK (1 or 2) output 

-

 

When OFF (1 or 2) is set to Ground  =>  0V with Anti-residual is applied on BK (1 or 2) output 

 

8.

 

(Optional):  To  get  an  Open  Loop  control  use  the  external  interface  power  supply  (10V  DC)  as  shown  figure  2  to  supply  a 

potentiometer or others as describe figure 5. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9.

 

Auxiliary Analog Sensor

 (Teachable Span)

 

 

In case of use an analog sensor or two, wire them to Pin  Ana1 or Ana2 and teach their voltage or current span with starting the 

calibration as describe below (for this use the button Cal as shown figure 6). 

If no calibration is done, Ana1 or Ana2 are ignored

.  

The Analog Input (Ana) compensates the Brake Input signal control

 

(InBK) between 20-100%.  

 

To Disable Ana1 or Ana2 compensation, please calibrate Ana 1 or 2 without any connection (unplugged).  

 

 

Figure 5: Typical Open Loop application with 

diameter compensation  

a.

 

Apply the brake at 0V or 4mA on InBK (1 or 2) or activate the Brake-Off (OFF1 or 

OFF2) 

b.

 

Check the Brake armature floats away from the Brake magnet with no sticking 

c.

 

If the armature sticks to the magnet, set the Anti-Residual (AntiR1 or AntiR2) as 

shown below until the armature is free with no sticking 

d.

 

Reapply the Brake at 10V or 20mA on InBK (1 or 2) or by returning the Brake-Off 

(OFF1 or 2) Pin to its normal position and activating the Brake-On input (ON1 or 

2) 

e.

 

If  Brake  releases  freely,  make  no  further  adjustments  as  the  Anti-Residual  is 

now set 

 

             X2DRV

 

       InBK        

Gnd             10VDC 

Ana 

Potentiometer 

Modulation 

between 20-100% 

 

Turn  the  trim  pot  clockwise  to 

increase the Anti-Residual 

Turn the trim pot Counterclockwise to 

decrease the Anti-Residual 

Figure 4: Anti-residual calibration 

AntiR  

(1 or 2) 

Potentiometer for Anti-residual setting 

Anti-residual adjustment 

Voltage Output versus anti-residual control 

24V 

10V or 

20mA 

Vout  0-24V 

Vin   

0-10V or 4-20mA 

AntiR

 

Reviews: