10.

 

(Optional):  The  frequency  adjustment  changes  the  modulation  frequency  to  eliminate  brake  “hum”  or  “howl”  when  the  brake  is 

stationary.  The  frequency  is  factory  set  and  normally  requires  no  adjustments.  Set  the  frequency  as  describe  below  with  the  red 

switches below the chassis:  

 

 

 

 

 

 

 

 

 

 

 

  

11.

 

Double check all wiring connections per figure 2 and insure all terminals are tight

 

 

Note: 

If an over-load occurs (current 4A more) the Driver output will shut down and the red LED will turn ON. To reset the system remove 

power to the Driver and turn it on again. 

X2DRV Block Diagram: 

 

“Teachable Span” calibration procedure 

    

Step 1

 

 

 
 
 

With the Auxiliary wired to Ana1 
or Ana2 
Press Cal button >5s.

 

 

 

    

Step 2

 

 
 
 
 

 
 

Put Min to Ana1 or Ana2 
Short press to valid: Min is learnt 

 

 

    

Step 3

 

 

 
 

Put Max to Ana1 or Ana2 
Short press to valid: Max is 
learnt and calibration is done 

 

 

 

Set 0:  Between 250 and 750 HZ 

 

 

Set 1: Between 1000 and 3000 HZ

 

 

Set 2: Between 2500 and 7500 HZ 

 

Set 3: Between 4250 and 10 KHZ 
(default) 

V/I

 

F1

 

F2

 

 

(rd) 

Red LED on 

 

(rd) 

Slow flashing 

 

 

 

F1 

F2 

F1 

F2 

 

 

F1 

F2 

 

 

F1 

F2 

 

 

Figure 6: Anti-residual setting and calibration 

Short press 

Cal 

Cal 

Short press 

Cal 

>5s 

(rd) 

Quick flashing 

 

On 

Off 

 

Turn the trim pot clockwise 

to increase the frequency 

Turn the trim pot 

counterclockwise to decrease 

Digital  

0-10V or 4-20mA 

Input Selectable 

Power Layers

 

OUTPUT Control: 

Pulse width modulated 4 Amps 

with Anti-residual Mode 

 

 

 

Brake 1 

 0-24V

 

or 0-4A 

Brake 2  

0-24V

 

  

or 0-4A 

Brake 2 ON 

Brake 2 OFF 

Brake 1 ON 

Brake 1 OFF 

LED1 State Brake 

 

LED2 State Brake 

 

AntiR1 Anti-Res 

Potentiometer

 

AntiR2 Anti-Res 

Potentiometer

 

POWER SUPPLY     

 24V DC +/- 5%, 4A 

10 VDC out 

Tension/Current 

Output Control 

 

 

 

Frequency 

Ana2 0-10V                   

or 4-20mA  

(Teach In) 

Ana1 0-10V                   

or 4-20mA  

(Teach In) 

InBK2 0-10V                   

or 4-20mA 

InBK1 0-10V                   

or 4-20mA 

Open Loop Digital Control  

 

InBK2 

X Gain 

Ana2 

Prop.2 

Calibration 

 

Open Loop Digital Control  

 

InBK1 

X Gain 

Ana1 

Prop.1 

Calibration 

 

Hardware interface 

 

Digital Input (Active low) 

Analog Input 

Analog Output

 

Setting

 

Cal 

AntiR 

LED 

Potentiometer for Anti-residual setting 

State LED 

Auxiliary Input Calibration: Ana1 & Ana2 