background image

 

 

Fig.1 

Fig.3 

Fig.6 

SITING: 

 

Avoid positioning above lightly coloured or polished surfaces.

 

 

Site carefully to avoid causing obstructions.

 

 

INSTALLATION: 

Remove the cover assembly using the hex key as shown. (Fig.1) Turn the 

2

 mounting screws fully

 

clockwise 

then slide the assembly forward in the direction shown. (Fig.2)  The cover assembly can 

now be removed from its backplate by rotating forward as shown. (Fig.3)

 

 

 

 

 

 

 

 

 

FIXING

 

Place the hand dryer at the desired location. A guide for recommended mounting height is described 
in Table 1. Using the backplate as a template, mark the position of the four fixing holes (Fig.4). Note; a 
keyhole slot is provided to aid installation. 
Drill the wall to accept the plugs and screws provided. Make provision for the electrical supply.  

 

 

                                                                                                                                              

 

 

 

 

 

 

 

WIRING 

The hand dryer must be connected to the supply via a fused, double-pole isolating switch having a 
contact separation of at least 3mm in all poles.

 

 

Feed the supply cable through the entry hole in the dryer base as shown. (Fig.5). 

 

Attach the dryer to the wall ensuring that it is secure. 

 

Connect the supply conductors as follows: 

BROWN

 wire to the terminal marked 

L

 

BLUE

 wire to the terminal marked 

N

 

 

Secure the cable beneath the cable clamp. Ensure that the clamp bears only on the outer 
sheathing (Fig.6) 

 

 
 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 
 
NOTE: This is a class 2 insulated product and does not require earth bonding. The terminal connector 
has the facility to ‘park’ an earth conductor if one is present. 
 
 

COVER RE-FITTING 
 

Installation is now complete and the cover should be replaced.  

 

Locate the cover assembly onto the backplate and slide downward into position. This is the 
reversal of the installation process in Fig’s 1, 2 & 3. 

 

Secure the cover assembly by rotating the 

2

 mounting screws 

anti-clockwise

DO NOT OVER 

TIGHTEN.

 

 

TESTING 
 

 

Switch on at the supply 

 

Place hands beneath the dryer. The dryer should start automatically. 

 

When the hands are removed the dryer should stop within a few seconds. 

 

 
 

                                                                        

Fig.2 

Fig.4 

Cable entry locations through 
base component 

Fixing holes 

Fig.5 

Cable Clamp 

Cable Entry 

Reviews: