For the cellulose weld stick, machine could be satisfied by E6011, E6010, E7018.
This kind of weld stick could satisfy whole position weld work request without welding fluid.
4 Operation control and connectors
§
4.1 Layout for front & rear panel
1. Power pilot lamp: This pilot lamp when lit indicates that the machine is on.
2. Alarm pilot lamp: This pilot lamp indicates when lit that the protection of the machine has been
activated.
3. Welding current regulation set welding current (5
– 160A).
4. Conversion switch choose (right), MMA, refer to
§
3.3.1
Choose (left), TIG, refer to
§
3.3.2
5. Earth connection Negative polarity output
6. Welding connection Positive polarity output
7. Cable clamp Fastened the mains cable
8. Mains switch