WARPP ENGINEERS PVT LTD
36/15,UNIQUE INDL ESTATE ,DHUMAL NAGAR ,WALIV PHATA ,VASAI(EAST)
C NO -8080808734
EMAIL - service@warpp.co.in
Note:
When the length of the cable is short the required cross
section for input cable will come down
Below table will help you in selecting the right size of welding
cable based on the length and current to be used.
Welding Cable selection chart
Welding
Current in
Amps
Recommended Cable size (Sq mm) based on
length (in Mtrs)
1 ~ 15
Mtrs
15 ~ 30
Mtrs
30 ~ 45
Mtrs
45 ~ 60
Mtrs
60 ~ 75
Mtrs
100
16
25
25
35
50
150
16
25
35
50
50
200
35
35
50
50
70
300
50
50
70
70
95
400
70
70
70
95
120
600
95
95
95
800
140
140
1000
140
190
1200
190
240
1500
240
285
Note:
Table given is just for reference and the actual result may vary
depending on the quality of conductor
Multiple cables can be used where every single cable of
that capacity is not available