background image

pb025nmdl4sm-rev1119

sandpiperpump

.

com

14

 • Model PB¼ Non-Metallic

Main Air Distribution Valve and Pilot Valve

1.2

1.1

1.1

1.4

1.4

1.3

1.5

6

28

4

11

1.4

26

3

17

28

5

15

10

21

27.1

27

26.1

1.3

1.5

Air Distribution Valve Servicing

See repair parts drawing, remove screws.

Step 1:

 Remove end cap retainer (1.5).

Step 2:

 Remove end cap (1.3).

Step 3:

 Remove spool part of (1.1) (caution: do not scratch).

Step 4:

 Press sleeve (1.1) from body (1.2).

Step 5:

 Inspect O-Rings (1-4) and replace if necessary.

Step 6: 

Lightly lubricate O-Rings (1-4) on sleeve (1.1).

Step 7:

 Press sleeve (1.1) into body (1.2).

Step 8: 

Reassemble in reverse order, starting with step 4.

Note: Sleeve and spool (1-1) set is match ground to a specified 

clearance. Sleeve and spools (1-1) cannot be interchanged.

Pilot Valve Servicing

With Pilot Valve removed from pump.

Step 1: 

Remove snap ring (21).

Step 2: 

Remove sleeve (26), inspect O-Rings (26.1),

replace if required.

Step 3:

 Remove spool (27) from sleeve (27.1),

inspect O-Rings (3E), replace if required.

Step 4: 

Lightly lubricate O-Rings (26.1) and (27.1).

Reassemble in reverse order.

Main Air Valve Assembly Parts List

Item     Part Number    Description 

Qty

1          031.107.551      Valve, Main Air 

  1

1.1       031.106.000      Sleeve and Spool Set (Includes O-Rings) 

  1

1.2       095.077.551      Body, Air Valve 

  1

1.3       165.074.551     Cap, End, Air Valve 

  2

1.4       560.101.360     O-Ring

  8

1.5       675.051.115     Ring, Retaining 

  2

ATEX Compliant 

IMPORTANT

Read these instructions completely, before installation 

and start-up. It is the responsibility of the purchaser 

to retain this manual for reference. Failure to comply 

with the recommendations stated in this manual will 

damage the pump, and void factory warranty.

Main Air Valve Assembly Parts List

Item     Part Number    Description 

Qty

1          031.107.503      Valve, Main Air (Conductive Acetal)  

  1

1.1       031.106.000      Sleeve and Spool Set (Includes O-Rings) 

  1

1.2       095.077.503      Body, Air Valve 

  1

1.3       165.074.503     Cap, End, Air Valve 

  2

1.4       560.101.360     O-Ring

  8

1.5       675.051.115     Ring, Retaining 

  2

Pilot Valve Assembly Parts List

Item     Part Number    Description

Qty

21        675.047.115      Ring, Retaining  

1

26        755.038.000      Sleeve, Pilot Valve (Includes O-Ring) 

1

26.1     560.066.360      O-Ring

6

27        775.038.000      Spool, Pilot Valve (Includes O-Ring) 

1

27.1     560.029.374      O-Ring

6

4: AIR 

END

Summary of Contents for Sandpiper PB 1/4

Page 1: ...n Rupp Inc A Unit of IDEX Corporation 800 N Main St Mansfield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2019 Warren Rupp Inc All rights reserved 1 PUMP SPECS 2...

Page 2: ...mperature range is as specified in tables 1 to 3 on the next page per Annex I of DEKRA 18ATEX0094X 2 ATEX compliant pumps are suitable for use in explosive atmospheres when the equipment is properly g...

Page 3: ...X 20 C to 50 C 20 C to 100 C T5 T100 X Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C 1 Per CSA standards ANSI LC6 2018 US Canadian Technical Letter R14 G Series Na...

Page 4: ...W 11 Composite Drawings Parts List Materials Code SECTION 4 AIR END 14 Air Distribution Valve Assembly Pilot Valve Solenoid Shifted Option Drawing Solenoid Shifted Air Distribution Valve Option SECTIO...

Page 5: ...oil E1 Integral Solenoid 24VDC Explosion Proof Coil E2 Integral Solenoid 24VAC 12VDC Coil E3 Integral Solenoid 12VDC Explosion Proof Coil E4 Integral Solenoid 110VAC Coil E5 Integral Solenoid 110VAC E...

Page 6: ...izing agents 180 F 82 C 32 F 0 C PVDF Polyvinylidene Fluoride A durable fluoroplastic with excellent chemical resistance Excellent for UV applications High tensile strength and impact resistance 250 F...

Page 7: ...olerance 125 3mm 4X 32 8 2 44 62 5 25 133 4X 19 5 7 90 201 6 65 169 4 00 102 7 52 191 OPTIONAL DISCHARGE PORT 1 4 FNPT PLUGGED OPTIONAL SUCTION PORT 1 4 FNPT PLUGGED AIR INLET PORT 1 4 FNPT 3 52 89 3...

Page 8: ...side check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanicall...

Page 9: ...p operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve ca...

Page 10: ...or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designed for 1 1 pressure ratio at zero flow Does not apply to high pressure 2 1 units Cavitation on suction side Che...

Page 11: ...End Kit Santoprene Diaphragms Balls 476 388 356 Wetted End Kit Hytrel Diaphragms Balls 476 388 600 Wetted End Kit PTFE Diaphragms Balls 476 388 644 Wetted End Kit Santoprene Diaphragms PTFE Balls 476...

Page 12: ...ytrel 4 286 070 600 Diaphragm PTFE 4 10 360 084 360 Gasket Intermediate 1 11 360 085 360 Gasket Valve Body 1 12 360 086 360 Gasket Spacer 2 13 518 210 552 Manifold Discharge Polypropylene Includes Plu...

Page 13: ...8 Cork and Neoprene 425 Compressed Fibre 426 Blue Gard 440 Vegetable Fibre 500 Delrin 500 502 Conductive Acetal ESD 800 503 Conductive Acetal Glass Filled 506 Delrin 150 520 Injection Molded PVDF Natu...

Page 14: ...ate O Rings 26 1 and 27 1 Reassemble in reverse order Main Air Valve Assembly Parts List Item Part Number Description Qty 1 031 107 551 Valve Main Air 1 1 1 031 106 000 Sleeve and Spool Set Includes O...

Page 15: ...r Description Qty 29 675 047 115 Ring Retaining Pilot Plug Sleeve 2 41 755 037 000 Pilot Plug Sleeve with O rings 1 42 360 106 360 Gasket Intermediate Bracket 1 43 241 001 000 Connector conduit 1 44 8...

Page 16: ...cle the pump s air distribution valve an electric solenoid is utilized As the solenoid is powered one of the pump s air chambers is pressurized while the other chamber is exhausted When electric power...

Page 17: ...by prying them out with a small flat screwdriver Step 2 After removing the inserts take the K R rod seals out of the inserts and replace Step 3 When reinstalling the seals make sure the open side of...

Page 18: ...nized Standard EN809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use...

Page 19: ...ies MSA Series U Series F Series T Series EH Series SH Series GH Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applie...

Reviews: