background image

pb025nmdl4sm-rev1119

sandpiperpump

.

com

Model PB¼ Non-Metallic • 

9

Principle of Pump Operation

SUBMERGED ILLUSTRATION

Installation And Start-Up

 

Locate the pump as close to the product being pumped as possible. Keep the suction line length and number of fittings to a minimum. Do not reduce the suction line 

diameter.

Air Supply

 

Connect the pump air inlet to an air supply with sufficient capacity and pressure to achieve desired performance. A pressure regulating valve should be installed to 

insure air supply pressure does not exceed recommended limits.

Air Valve Lubrication

 

The air distribution system is designed to operate WITHOUT lubrication. This is the standard mode of operation. If lubrication is desired, install an air line lubricator 

set to deliver one drop of SAE 10 non-detergent oil for every 20 SCFM (9.4 liters/sec.) of air the pump consumes. Consult the Performance Curve to determine air 

consumption.

Air Line Moisture

 

Water in the compressed air supply may cause icing or freezing of the exhaust air, causing the pump to cycle erratically or stop operating. Water in the air supply can 

be reduced by using a point-of-use air dryer.

Air Inlet And Priming

 

To start the pump, slightly open the air shut-off valve. After the pump primes, the air valve can be opened to increase air flow as desired. If opening the valve 

increases cycling rate, but does not increase the rate of flow, cavitation has occurred. The valve should be closed slightly to obtain the most efficient air flow to pump 

flow ratio.

1  Surge Suppressor

Flexible Connector

Pipe Connection

(Style Optional)

Shut-Off Valve

Pressure Gauge

Drain Port

Muffler

(Optional Piped Exhaust)

Flexible

Connection

3  Dryer

2  Filter Regulator

Unregulated Air

Supply to Surge

Suppressor

Shut Off

Valve

Flexible Connector

Pipe Connection

(Style Optional)

Drain Port

Shut-Off Valve

Compound

Gauge

Note

: Surge Suppressor and

          Piping, including air line,

          must be supported after

          the flexible connections.

Check

Valve

Air Inlet

Suction

Discharge

4  Lubricator

Recommended Installation Guide

Available Accessories:

1.

Surge Suppressor

2.

Filter/Regulator

3.

Air Dryer

4.

Lubricator

CAUTION

The air exhaust should 

be  piped to an area 

for safe  disposition 

of the product  being 

pumped, in the event  of 

a diaphragm failure.

2: INST

AL

 & OP

Summary of Contents for Sandpiper PB 1/4

Page 1: ...n Rupp Inc A Unit of IDEX Corporation 800 N Main St Mansfield Ohio 44902 USA Telephone 419 524 8388 Fax 419 522 7867 SANDPIPERPUMP COM Copyright 2019 Warren Rupp Inc All rights reserved 1 PUMP SPECS 2...

Page 2: ...mperature range is as specified in tables 1 to 3 on the next page per Annex I of DEKRA 18ATEX0094X 2 ATEX compliant pumps are suitable for use in explosive atmospheres when the equipment is properly g...

Page 3: ...X 20 C to 50 C 20 C to 100 C T5 T100 X Ambient Temperature Range C Process Temperature Range C 20 C to 60 C 20 C to 150 C 1 Per CSA standards ANSI LC6 2018 US Canadian Technical Letter R14 G Series Na...

Page 4: ...W 11 Composite Drawings Parts List Materials Code SECTION 4 AIR END 14 Air Distribution Valve Assembly Pilot Valve Solenoid Shifted Option Drawing Solenoid Shifted Air Distribution Valve Option SECTIO...

Page 5: ...oil E1 Integral Solenoid 24VDC Explosion Proof Coil E2 Integral Solenoid 24VAC 12VDC Coil E3 Integral Solenoid 12VDC Explosion Proof Coil E4 Integral Solenoid 110VAC Coil E5 Integral Solenoid 110VAC E...

Page 6: ...izing agents 180 F 82 C 32 F 0 C PVDF Polyvinylidene Fluoride A durable fluoroplastic with excellent chemical resistance Excellent for UV applications High tensile strength and impact resistance 250 F...

Page 7: ...olerance 125 3mm 4X 32 8 2 44 62 5 25 133 4X 19 5 7 90 201 6 65 169 4 00 102 7 52 191 OPTIONAL DISCHARGE PORT 1 4 FNPT PLUGGED OPTIONAL SUCTION PORT 1 4 FNPT PLUGGED AIR INLET PORT 1 4 FNPT 3 52 89 3...

Page 8: ...side check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanicall...

Page 9: ...p operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off valve After the pump primes the air valve ca...

Page 10: ...or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is designed for 1 1 pressure ratio at zero flow Does not apply to high pressure 2 1 units Cavitation on suction side Che...

Page 11: ...End Kit Santoprene Diaphragms Balls 476 388 356 Wetted End Kit Hytrel Diaphragms Balls 476 388 600 Wetted End Kit PTFE Diaphragms Balls 476 388 644 Wetted End Kit Santoprene Diaphragms PTFE Balls 476...

Page 12: ...ytrel 4 286 070 600 Diaphragm PTFE 4 10 360 084 360 Gasket Intermediate 1 11 360 085 360 Gasket Valve Body 1 12 360 086 360 Gasket Spacer 2 13 518 210 552 Manifold Discharge Polypropylene Includes Plu...

Page 13: ...8 Cork and Neoprene 425 Compressed Fibre 426 Blue Gard 440 Vegetable Fibre 500 Delrin 500 502 Conductive Acetal ESD 800 503 Conductive Acetal Glass Filled 506 Delrin 150 520 Injection Molded PVDF Natu...

Page 14: ...ate O Rings 26 1 and 27 1 Reassemble in reverse order Main Air Valve Assembly Parts List Item Part Number Description Qty 1 031 107 551 Valve Main Air 1 1 1 031 106 000 Sleeve and Spool Set Includes O...

Page 15: ...r Description Qty 29 675 047 115 Ring Retaining Pilot Plug Sleeve 2 41 755 037 000 Pilot Plug Sleeve with O rings 1 42 360 106 360 Gasket Intermediate Bracket 1 43 241 001 000 Connector conduit 1 44 8...

Page 16: ...cle the pump s air distribution valve an electric solenoid is utilized As the solenoid is powered one of the pump s air chambers is pressurized while the other chamber is exhausted When electric power...

Page 17: ...by prying them out with a small flat screwdriver Step 2 After removing the inserts take the K R rod seals out of the inserts and replace Step 3 When reinstalling the seals make sure the open side of...

Page 18: ...nized Standard EN809 2012 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use...

Page 19: ...ies MSA Series U Series F Series T Series EH Series SH Series GH Series Conductive plastic pump models with integral muffler S Series PB Series Tranquilizer surge suppressors Hazardous Location Applie...