ME
IMO Tier 2
AUX
IMO Tier 2
AUX
IMO Tier 2
DE
IMO Tier 2
DE
IMO Tier 2
Wärtsilä 12V31
750
610
750
610
720
590
750
610
720
590
RPM
kW/cyl
Engine speed
Cylinder output
176.6
181.9
180.9
181.4
180.4
g/kWh
Fuel consumption at 50% load, MDF
26.5
26.6
25.6
26.5
25.5
kg/h
Clean leak fuel quantity, MDF at 100% load
5.3
5.3
5.1
5.3
5.1
kg/h
Clean leak fuel quantity, HFO at 100% load
Lubricating oil system
420
420
420
420
420
kPa
Pressure before bearings, nom. (PT 201)
40
40
40
40
40
kPa
Suction ability main pump, including pipe loss, max.
60
60
60
60
60
kPa
Priming pressure, nom. (PT 201)
35
35
35
35
35
kPa
Suction ability priming pump, including pipe loss, max.
70
70
70
70
70
°C
Temperature before bearings, nom. (TE 201)
82
82
82
82
82
°C
Temperature after engine, approx.
170
144
138
144
138
m³/h
Pump capacity (main), engine driven
137
137
137
137
137
m³/h
Pump capacity (main), stand-by
29.0 / 29.0
29.0 / 29.0
29.0 / 29.0
29.0 / 29.0
29.0 / 29.0
m³/h
Priming pump capacity, 50Hz/60Hz
3.3
3.3
3.3
3.3
3.3
m³
Oil volume, wet sump, nom.
9.9
9.9
9.6
9.9
9.6
m³
Oil volume in separate system oil tank, nom.
0.45
0.45
0.45
0.45
0.45
g/kWh
Oil consumption (100% load), approx.
2940
2940
2940
2940
2940
l/min
Crankcase ventilation flow rate at full load
0.1
0.1
0.1
0.1
0.1
kPa
Crankcase ventilation backpressure, max.
6.0...6.8
6.0...6.8
6.0...6.8
6.0...6.8
6.0...6.8
liters
Oil volume in turning device
Cooling water system
High temperature cooling water system
363 + stat-
ic
363 + stat-
ic
363 + stat-
ic
363 + stat-
ic
363 + stat-
ic
kPa
Pressure at engine, after pump, nom. (PT 401)
600
600
600
600
600
kPa
Pressure at engine, after pump, max. (PT 401)
83
83
83
83
83
°C
Temperature before cylinders, approx. (TE 401)
96
96
96
96
96
°C
HT-water out from engine, nom (TE432)
110
110
110
110
110
m³/h
Capacity of engine driven pump, nom.
210
210
210
210
210
kPa
Pressure drop over engine, total
100
100
100
100
100
kPa
Pressure drop in external system, max.
70...150
70...150
70...150
70...150
70...150
kPa
Pressure from expansion tank
m³
Water volume in engine
Low temperature cooling water system
25 ... 38
25 ... 38
25 ... 38
25 ... 38
25 ... 38
°C
Temperature before engine (TE 451)
110
110
110
110
110
m³/h
Capacity of engine driven pump, nom.
41
41
41
41
41
kPa
Pressure drop over charge air cooler (one-stage)
110
110
110
110
110
kPa
Pressure drop over charge air cooler (two-stage)
115
115
115
115
115
kPa
Pressure drop over oil cooler
100
100
100
100
100
kPa
Pressure drop in external system, max.
3-8
Wärtsilä 31 Product Guide - a1 - 18 October 2016
Wärtsilä 31 Product Guide
3. Technical Data
Summary of Contents for 31
Page 1: ...PRODUCT GUIDE W rtsil 31...
Page 6: ...This page intentionally left blank...
Page 10: ...This page intentionally left blank...
Page 30: ...This page intentionally left blank...
Page 36: ...This page intentionally left blank...
Page 44: ...This page intentionally left blank...
Page 88: ...This page intentionally left blank...
Page 116: ...This page intentionally left blank...
Page 134: ...This page intentionally left blank...
Page 138: ...14 4 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Page 140: ...14 6 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Page 148: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 154: ...This page intentionally left blank...
Page 160: ...This page intentionally left blank...
Page 162: ...This page intentionally left blank...
Page 165: ......
Page 166: ......
Page 167: ......