50°C
Design temperature
Larger than feed/circulation pump capacity
Design flow
1.6 MPa (16 bar)
Design pressure
25
μ
m (absolute mesh size)
Fineness
Maximum permitted pressure drops at 14 cSt:
20 kPa (0.2 bar)
- clean filter
80 kPa (0.8 bar)
- alarm
6.3.4.4
Pressure control valve, MDF (1V02)
The pressure control valve is installed when the installation includes a feeder/booster unit for
HFO and there is a return line from the engine to the MDF day tank. The purpose of the valve
is to increase the pressure in the return line so that the required pressure at the engine is
achieved.
Design data:
Equal to circulation pump
Capacity
50°C
Design temperature
1.6 MPa (16 bar)
Design pressure
0.4...0.7 MPa (4...7 bar)
Set point
6.3.4.5
MDF cooler (1E04)
The fuel viscosity may not drop below the minimum value stated in Technical data. When
operating on MDF, the practical consequence is that the fuel oil inlet temperature must be
kept below 45°C. Very light fuel grades may require even lower temperature.
Sustained operation on MDF usually requires a fuel oil cooler. The cooler is to be installed in
the return line after the engine(s). LT-water is normally used as cooling medium.
If MDF viscosity in day tank drops below stated minimum viscosity limit then it is recommended
to install an MDF cooler into the engine fuel supply line in order to have reliable viscosity
control.
Design data:
80 kPa (0.8 bar)
Max. pressure drop, fuel oil
60 kPa (0.6 bar)
Max. pressure drop, water
min. 15%
Margin (heat rate, fouling)
50/150°C
Design temperature MDF/HFO installa-
tion
Wärtsilä 31 Product Guide - a1 - 18 October 2016
6-17
6. Fuel Oil System
Wärtsilä 31 Product Guide
Summary of Contents for 31
Page 1: ...PRODUCT GUIDE W rtsil 31...
Page 6: ...This page intentionally left blank...
Page 10: ...This page intentionally left blank...
Page 30: ...This page intentionally left blank...
Page 36: ...This page intentionally left blank...
Page 44: ...This page intentionally left blank...
Page 88: ...This page intentionally left blank...
Page 116: ...This page intentionally left blank...
Page 134: ...This page intentionally left blank...
Page 138: ...14 4 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Page 140: ...14 6 W rtsil 31 Product Guide a1 18 October 2016 W rtsil 31 Product Guide 14 Foundation...
Page 148: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 154: ...This page intentionally left blank...
Page 160: ...This page intentionally left blank...
Page 162: ...This page intentionally left blank...
Page 165: ......
Page 166: ......
Page 167: ......