Example of required power, oil temperature 40°C.
16V46F
14V46F
12V46F
9L46F
8L46F
7L46F
6L46F
11.5
11.5
10
8
6
6
5
Pump [kW]
15
15
15
11
7.5
7.5
7.5
Electric motor [kW]
Example of required power, oil temperature 20°C.
16V46F
14V46F
12V46F
9L46F
8L46F
7L46F
6L46F
17.5
17.5
23
17
14
14
11
Pump [kW]
22
22
30
18.5
15
15
15
Electric motor [kW]
7.3.6
Automatic filter (2F02)
When off-engine main filter, it is recommended to select an automatic filter with an insert filter
in the bypass line, thus enabling easy changeover to the insert filter during maintenance of
the automatic filter.
Automatic filters are commonly equipped with an integrated safety filter. However, some
automatic filter types, especially automatic filter designed for high flows, may not have the
safety filter built-in. In such case a separate safety filter (2F05) must be installed before the
engine.
Design data:
50 cSt (SAE 40, VI 95, appox. 63°C)
Oil viscosity
see Technical data, "Oil flow through engine"
Design flow
100°C
Design temperature
1.0 MPa (10 bar)
Design pressure
Fineness:
35 µm (absolute)
- automatic filter
35 µm (absolute)
- insert filter
Max permitted pressure drops at 50 cSt:
30 kPa (0.3 bar )
- clean filter
80 kPa (0.8 bar)
- alarm
7.3.7
Safety filter (2F05)
When off-engine main filter, a separate safety filter (2F05) must be installed before the engine,
unless it is integrated in the automatic filter. The safety filter (2F05) should be a duplex filter
with steelnet filter elements.
Design data:
50 cSt (SAE 40, VI 95, appox. 63°C)
Oil viscosity
see Technical data, "Oil flow through engine"
Design flow
100 °C
Design temperature
1.0 MPa (10 bar)
Design pressure
7-14
DAAB605814
Wärtsilä 46F Product Guide
7. Lubricating Oil System
Summary of Contents for 46F Series
Page 1: ...Wärtsilä 46F PRODUCT GUIDE ...
Page 4: ...This page intentionally left blank ...
Page 8: ...This page intentionally left blank ...
Page 18: ...This page intentionally left blank ...
Page 86: ...This page intentionally left blank ...
Page 104: ...This page intentionally left blank ...
Page 154: ...This page intentionally left blank ...
Page 162: ...This page intentionally left blank ...
Page 170: ...This page intentionally left blank ...
Page 176: ...This page intentionally left blank ...
Page 194: ...This page intentionally left blank ...
Page 200: ...This page intentionally left blank ...
Page 202: ...This page intentionally left blank ...
Page 207: ...Fig 21 7 List of symbols DAAF406507 7 DAAB605814 21 5 21 ANNEX Wärtsilä 46F Product Guide ...