Fig 7-5
Example of system oil tank arrangement (DAAE007020e)
Design data:
1.2...1.5 l/kW, see also Technical data
Oil tank volume
75...80% of tank volume
Oil level at service
60% of tank volume
Oil level alarm
7.3.5
Gravity tank (2T02)
In installations without engine driven pump it is required to have a lubricating oil gravity tank,
to ensure some lubrication during the time it takes for the engine to stop rotating in a blackout
situation.
The required height of the tank is about 7 meters above the crankshaft. A minimum pressure
of 50 kPa (0.5 bar) must be measured at the inlet to the engine.
Tank volume [m
3
]
Engine type
1.0
6L50DF
2.0
8L-, 9L-, 12V50DF
7-10
Wärtsilä 50DF Product Guide - a16 - 9 September 2016
Wärtsilä 50DF Product Guide