Fig 7-8
Condensate trap
(DAAE032780B)
The size of the ventilation pipe (D2) out
from the condensate trap should be
bigger than the ventilation pipe (D) com-
ing from the engine.
For more information about ventilation
pipe (D) size, see the external lubricating
oil system drawing.
The max. back-pressure must also be
considered when selecting the ventilation
pipe size.
Wärtsilä 50DF Product Guide - a16 - 9 September 2016
7-15
7. Lubricating Oil System
Wärtsilä 50DF Product Guide