9.2
Internal cooling water system
Fig 9-1
Internal cooling water system, two stage air cooler, in-line engines
(DAAE005313C)
System components:
Shut-off valve
07
Lubricating oil cooler
04
HT-cooling water pump
01
Connection piece
08
HT-thermostatic valve
05
LT-cooling water pump
02
Charge air cooler (HT)
09
LT-thermostatic valve
06
Charge air cooler (LT)
03
Sensors and indicators:
HT-water temperature, engine outlet
TE402
HT-water stand-by pump start
PS410
HT-water temperature, CAC outlet
TE432
LT-water stand-by pump start
PS460
LT-water temperature, LT CAC inlet
TE471
HT-water pressure, engine inlet
PT401
LT-water temperature, LOC inlet
TE482
LT-water pressure, LT CAC inlet
PT471
HT-water temp, jacket outlet A-bank
TEZ402
HT-water temperature, engine inlet
TE401
Standard
Pressure class
Size
Pipe connections:
ISO 7005-1
PN16
DN100
HT-water inlet
401
ISO 7005-1
PN16
DN100
HT-water outlet
402
DIN 2353
OD12
HT-water air vent
404
DIN 2353
OD28
Water from preheater to HT-circuit
406
ISO 7005-1
PN16
DN100
HT-water from stand-by pump
408
ISO 7005-1
PN16
DN100
LT-water inlet
451
ISO 7005-1
PN16
DN100
LT-water outlet
452
DIN 2353
OD12
LT-water air vent from air cooler
454
ISO 7005-1
PN16
DN100
LT-water from stand-by pump
457
9-2
Wärtsilä 32 Product Guide - a21 - 7 September 2016
Wärtsilä 32 Product Guide
9. Cooling Water System
Summary of Contents for WARTSILA32
Page 18: ...This page intentionally left blank...
Page 72: ...This page intentionally left blank...
Page 130: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 186: ...This page intentionally left blank...
Page 204: ...This page intentionally left blank...
Page 210: ...This page intentionally left blank...
Page 216: ...This page intentionally left blank...
Page 238: ...This page intentionally left blank...
Page 246: ...This page intentionally left blank...
Page 248: ...This page intentionally left blank...
Page 251: ......
Page 252: ......
Page 253: ......