Fig 9-6
Example diagram for single main engine (HFO) reduction gear sea water
cooled (3V76C5791B)
System components:
Stand-by pump (LT)
4P05
Heater (preheater)
4E05
Transfer pump
4P09
Central cooler
4E08
Circulating pump (sea water)
4P11
Cooler (reduction gear)
4E10
Air venting
4S01
Suction strainer (sea water)
4F01
Drain tank
4T04
Preheating unit
4N01
Expansion tank
4T05
Stand-by pump (HT)
4P03
Temp control valve (central cooler)
4V08
Circulating pump (preheater)
4P04
Pipe connections:
DN100
LT-water inlet
451
DN100
HT-water inlet
401
DN100
LT-water outlet
452
DN100
HT-water outlet
402
OD12
LT-water air venting from air cooler
454
OD12
HT-water air vent
404
DN100
LT-water from stand-by pump
457
OD28
Water from preheater to HT-circuit
406
DN100
HT-water from stand-by pump
408
Wärtsilä 32 Product Guide - a21 - 7 September 2016
9-7
9. Cooling Water System
Wärtsilä 32 Product Guide
Summary of Contents for WARTSILA32
Page 18: ...This page intentionally left blank...
Page 72: ...This page intentionally left blank...
Page 130: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 186: ...This page intentionally left blank...
Page 204: ...This page intentionally left blank...
Page 210: ...This page intentionally left blank...
Page 216: ...This page intentionally left blank...
Page 238: ...This page intentionally left blank...
Page 246: ...This page intentionally left blank...
Page 248: ...This page intentionally left blank...
Page 251: ......
Page 252: ......
Page 253: ......