DE
SCR
mode
AE
SCR
mode
DE
IMO
Tier 2
AE
IMO
Tier 2
Wärtsilä 8L32
720
560
720
560
720
560
720
560
RPM
kW/cyl
Engine speed
Cylinder output
250 +
static
250 +
static
250 +
static
250 +
static
kPa
Pressure at engine, after pump, nom. (PT 451)
530
530
530
530
kPa
Pressure at engine, after pump, max. (PT 451)
25 ... 38
25 ... 38
25 ... 38
25 ... 38
°C
Temperature before engine (TE 451)
75
75
75
75
m³/h
Capacity of engine driven pump, nom.
35
35
35
35
kPa
Pressure drop over charge air cooler
30
30
30
30
kPa
Pressure drop over oil cooler
100
100
100
100
kPa
Pressure drop in external system, max.
70 ...
150
70 ...
150
70 ...
150
70 ...
150
kPa
Pressure from expansion tank
Starting air system (Note 5)
3000
3000
3000
3000
kPa
Pressure, nom.
1600
1600
1600
1600
kPa
Pressure at engine during start, min. (20°C)
3000
3000
3000
3000
kPa
Pressure, max.
1600
1600
1600
1600
kPa
Low pressure limit in air vessels (alarm limit)
2.7
2.7
2.7
2.7
Nm
3
Air consumption per start
-
-
-
-
Nm
3
Air consumption per start without propeller shaft
engaged
-
-
-
-
Nm
3
Air consumption per start with propeller shaft en-
gaged
1.33
1.33
1.33
1.33
Nm
3
Air assist consumption (for engines with 580 kW/cyl)
Notes:
At ISO 15550 conditions (ambient air temperature 25°C, LT-water 25°C) and 100% load. Flow tolerance 5%.
Note 1
At ISO 15550 conditions (ambient air temperature 25°C, LT-water 25°C). Flow tolerance 5% and temperature tolerance
10°C.
Note 2
At ISO 15550 conditions (ambient air temperature 25°C, LT-water 25°C) and 100% load. Tolerance for cooling water heat
10%, tolerance for radiation heat 30%. Fouling factors and a margin to be taken into account when dimensioning heat
exchangers.
Note 3
At ambient conditions according to ISO 15550. Lower calorific value 42 700 kJ/kg. With engine driven pumps (two cooling
water + one lubricating oil pump). Tolerance 5%. Note; SOI is different for MDO and HFO engines. If the engine is made
for operation on both HFO and MDO, the consumption on both fuels will be according to HFO consumption.
Note 4
Automatic (remote or local) starting air consumption (average) per start, at 20°C for a specific long start impulse (DE/AUX:
2...3 sec, CPP/FPP: 4...6 sec) which is the shortest time required for a safe start.
Note 5
ME = Engine driving propeller, variable speed
AE = Auxiliary engine driving generator
DE = Diesel-Electric engine driving generator
Subject to revision without notice.
3-10
Wärtsilä 32 Product Guide - a21 - 7 September 2016
Wärtsilä 32 Product Guide
3. Technical Data
Summary of Contents for WARTSILA32
Page 18: ...This page intentionally left blank...
Page 72: ...This page intentionally left blank...
Page 130: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 186: ...This page intentionally left blank...
Page 204: ...This page intentionally left blank...
Page 210: ...This page intentionally left blank...
Page 216: ...This page intentionally left blank...
Page 238: ...This page intentionally left blank...
Page 246: ...This page intentionally left blank...
Page 248: ...This page intentionally left blank...
Page 251: ......
Page 252: ......
Page 253: ......