3.4
Wärtsilä 8L32, 750 rpm
ME
SCR
mode
DE
SCR
mode
AE
SCR
mode
ME
IMO
Tier 2
DE
IMO
Tier 2
AE
IMO
Tier 2
Wärtsilä 8L32
750
580
750
580
750
580
750
580
750
580
750
580
RPM
kW/cyl
Engine speed
Cylinder output
4640
4640
4640
4640
4640
4640
kW
Engine output
2.88
2.88
2.88
2.88
2.88
2.88
MPa
Mean effective pressure
Combustion air system (Note 1)
8.15
8.35
8.35
8.15
8.35
8.35
kg/s
Flow at 100% load
45
45
45
45
45
45
°C
Temperature at turbocharger intake, max.
55
55
55
55
55
55
°C
Air temperature after air cooler (TE 601)
Exhaust gas system (Note 2)
8.4
8.6
8.6
8.4
8.6
8.6
kg/s
Flow at 100% load
7.2
7.2
7.2
7.5
7.8
7.8
kg/s
Flow at 85% load
6.5
6.5
6.5
6.5
7.1
7.1
kg/s
Flow at 75% load
4.5
4.8
4.8
4.5
4.8
4.8
kg/s
Flow at 50% load
370
350
350
370
350
350
°C
Temperature after turbocharger, 100% load
(TE 517)
340
340
340
330
320
320
°C
Temperature after turbocharger, 85% load
(TE 517)
340
340
340
340
320
320
°C
Temperature after turbocharger, 75% load
(TE 517)
350
360
360
350
360
360
°C
Temperature after turbocharger, 50% load
(TE 517)
5.0
5.0
5.0
5.0
5.0
5.0
kPa
Backpressure, max.
744
741
741
744
741
741
mm
Calculated pipe diameter for 35m/s
Heat balance (Note 3)
587
599
599
587
599
599
kW
Jacket water, HT-circuit
1081
1065
1065
1081
1065
1065
kW
Charge air, HT-circuit
652
641
641
652
641
641
kW
Charge air, LT-circuit
528
540
540
528
540
540
kW
Lubricating oil, LT-circuit
147
147
147
147
147
147
kW
Radiation
Fuel system (Note 4)
700±50
700±50
700±50
700±50
700±50
700±50
kPa
Pressure before injection pumps (PT 101)
5.6
5.6
5.6
5.6
5.6
5.6
m
3
/h
Engine driven pump capacity (MDF only)
4.7
4.7
4.7
4.7
4.7
4.7
m
3
/h
Fuel flow to engine (without engine driven
pump), approx.
16...24
16...24
16...24
16...24
16...24
16...24
cSt
HFO viscosity before engine
140
140
140
140
140
140
°C
HFO temperature before engine, max. (TE
101)
2.0
2.0
2.0
2.0
2.0
2.0
cSt
MDF viscosity, min
45
45
45
45
45
45
°C
MDF temperature before engine, max. (TE
101)
184
185
185
183
183
184
g/kWh
Fuel consumption at 100% load, HFO
183
185
185
180
182
183
g/kWh
Fuel consumption at 85% load, HFO
183
185
185
180
182
183
g/kWh
Fuel consumption at 75% load, HFO
Wärtsilä 32 Product Guide - a21 - 7 September 2016
3-11
3. Technical Data
Wärtsilä 32 Product Guide
Summary of Contents for WARTSILA32
Page 18: ...This page intentionally left blank...
Page 72: ...This page intentionally left blank...
Page 130: ...This page intentionally left blank...
Page 150: ...This page intentionally left blank...
Page 186: ...This page intentionally left blank...
Page 204: ...This page intentionally left blank...
Page 210: ...This page intentionally left blank...
Page 216: ...This page intentionally left blank...
Page 238: ...This page intentionally left blank...
Page 246: ...This page intentionally left blank...
Page 248: ...This page intentionally left blank...
Page 251: ......
Page 252: ......
Page 253: ......