background image

16

Installation manual

Loosen the nuts and move the two brackets to the opposite side.

fig.7171

Move the door switch on the front panel.

1

2

3

4

fig.7172

Summary of Contents for D7-550

Page 1: ...Installation manual Tumble dryer D7 550 Type N2 Original instructions 438905413 EN 2023 02 27...

Page 2: ......

Page 3: ...fier 24 8 Gas connection 25 8 1 Fasten the label 25 8 2 General 25 8 3 Gas installation 26 8 4 Table of pressure and adjustment 27 8 5 Test run 28 8 6 Converting instructions 29 8 7 Data label 30 9 El...

Page 4: ......

Page 5: ...st not be installed behind a lockable door a sliding door or a door with a hinge on the opposite side to that of the machine in such a way that a full opening of the machine is restricted If the machi...

Page 6: ...owing countries AT BE BG HR CY CZ DK EE FI FR DE GR HU IS IE IT LV LT LU MT NL NO PL PT RO SK SI ES SE CH TR UK The appliance can be used in public areas This appliance can be used by children aged fr...

Page 7: ...se of doubt the installer shall contact the supplier The appliance should be installed on non flammable materials for the floor worktop and or wall close to the appliance if required If you can smell...

Page 8: ...H J I F K M N L 1 2 7 6 5 6 3 7 3 4 5 1 Operating panel 2 Door opening 810 mm 3 Electrical connection 4 Gas connection 5 Exhaust connection 6 Steam in 7 Steam out A B a B b C D E mm 960 1365 1445 1855...

Page 9: ...Hz 60 Hz m3 h 1080 1080 Maximum static back pressure Electric 50 Hz 60 Hz Pa 480 950 Maximum static back pressure Gas 50 Hz 60 Hz Pa 420 900 Maximum static back pressure Steam 50 Hz 60 Hz Pa 1300 155...

Page 10: ...the machine and two in the back of the machine Remove the lower front panel and remove the two bolts in the front of the machine Remove the low er rear panel and remove the two bolts in the back of t...

Page 11: ...r packaging 4 5 6 7 3 1 2 fig X02402 Fig Description Code Type 1 Wrapping film LDPE 4 Plastics 2 Corner protection PS 6 Plastics 3 Cardboard packaging PAP 20 Paper 4 Pallet FOR 50 Wood 5 Screw FE 40 S...

Page 12: ...the gap above the machine Min required clearance 0 mm Note The machine should be positioned so that there will be enough space for working both for the user and service personnel Respecting the given...

Page 13: ...o the foundation Fasten the four fittings A to the foundation using four x M10 set screws B If the four fittings are not supplied order kit No 487193544 Fasten the machine to the fittings M10 15 3 mm...

Page 14: ...ine machine model to the foundation using four x M10 set screws If the four fittings are not supplied order kit No 487193544 Fasten the machine to the fittings Note Marine installation is not applicab...

Page 15: ...7166 Remove the screws on the front panel and carefully loosen the panel Push the door switch cable down through the hole in order to access the cable and then disconnect the cable Remove the panel fi...

Page 16: ...16 Installation manual Loosen the nuts and move the two brackets to the opposite side fig 7171 Move the door switch on the front panel 1 2 3 4 fig 7172...

Page 17: ...witch cable and push the cable in over the drum and pull it upwards fig 7549 Remount the front panel Ensure that the door switch cable does not get damaged when remounting the front panel Fasten the h...

Page 18: ...e heating unit The heated air passes through the garments and the drum holes The air then flows out through a lint filter positioned below the drum Then the air is evacuated through the fan and exhaus...

Page 19: ...atted covers often block half of the total fresh air vent area Remember to take this into account 6 3 Exhaust duct Only rigid or flexible metal duct should be used for exhausting Plastic ducting is no...

Page 20: ...a of fresh air intake m2 0 16 0 39 0 63 0 63 0 98 0 98 1 56 1 56 1 56 2 51 Minimum area of fresh air intake Gas heated Electric heated m2 0 05 0 1 0 15 0 2 0 25 0 3 0 35 0 4 0 45 0 5 Minimum area of f...

Page 21: ...suring device Make sure the connection is tight to prevent air leakage Loosen the screws on the damper and open the damper B as much as possible A B fig 7524 Measure with a pressure measuring instrume...

Page 22: ...sert one end of the hose in the hole hold the hose according to the picture so that the water is in level Start the machine and measure the difference between the water in one of the hose ends with th...

Page 23: ...is recommended to in stall a steam trap F 5 6 A B D E C F fig 7194B Attach the pressure hoses to the machines inlet and outlet connecting branches It is important to support the inlet and the outlet c...

Page 24: ...me way A Hang the calorifier on the bottom supporting rail on the machine Hold the calorifier towards the machine and remount the supporting rail Make sure that it grasps the calorifier Fasten the cal...

Page 25: ...Art No GB IE Read the technical instructions before installing the appli ance Read the user instructions before lighting the appliance This appliance may only be installed in a room if the room meets...

Page 26: ...L Albania IE Ireland AT Austria IS Iceland BE Belgium IT Italy BG Bulgaria LT Lithuania CH Switzerland LU Luxembourg CY Cyprus LV Latvia CZ Czech Republic MK Republic of Macedonia DE Germany MT Malta...

Page 27: ...n follow ing countries Butane mixture Propane mixture 3 28 30 37 No regulation 2 00 490359204 A 20 490375653 BE CH CY CZ ES FR GB GR IE IT LT LU LV PT SK SI Butane 3B P 30 37 50 28 2 00 490359204 A 20...

Page 28: ...2 2LL G25 20 12 3 50 490359201 A 18 490375652 DE A When a machine with liquid petroleum gases shall be installed or used on high altitude 2001 feet and higher a kit for high altitude must be installed...

Page 29: ...new air reducing plates according to the table 1 fig 7182 Loosen the measuring branch screw 2 1 4 turn connect a manometer to the measuring branch Connect the power to the machine and select a progra...

Page 30: ...al no OC number Date YYMM Capacity Type Model Voltage Rated Input For safety reasons use only genuine spare parts Made in Sweden Electrolux Professional AB 341 80 Ljungby Sweden Product no Serial no P...

Page 31: ...ensure that the appropriate type of breaker is chosen and that the dimensioning is correct for maximum reliability connect only one machine per earth leakage circuit breaker it is important that the e...

Page 32: ...e supply unit Connect the earth and other wires as shown 3AC 3AC L1 L2 L3 3NAC 3NAC L1 L2 L3 N When the installation is completed remount the cover panel and check That the drum is empty That the mach...

Page 33: ...18 0 24 0 32 0 19 5 25 5 33 5 50 80 100 240V 3 50 60 18 0 24 0 32 0 19 5 25 5 33 5 50 63 100 380 415V 3N 3 50 60 18 0 24 0 32 0 19 5 25 5 33 5 32 50 50 440V 3 60 24 0 32 0 26 7 34 7 35 50 480V 3 60 24...

Page 34: ...system must transmit a start pulse 300 3000 ms 500 ms is recommended with a minimum pause of 300 ms 500 ms is recommended between two pulses The start pulse can be either 230V or 24V In order to rece...

Page 35: ...chine The signal must remain active high during drying When the signal gets inactive low the machine will abort ongoing program and enter cooling The signal can be either 230V or 24V In order to re ce...

Page 36: ...3 External coin meter Central payment 2K The signal received from external coin meters must be a pulse between 300 3000 ms 500 ms is recommended with a minimum pause of 300 ms 500 ms is recommended b...

Page 37: ...rogram is reduced or the time is increased on time programs by the percent age entered in the price programming menu fig 7441 9 6 Option 9 6 1 External connection 100 mA A special connection terminal...

Page 38: ...essages program names etc will be presented in 10 2 Set time and date Select YES and press the start button to get to the TIME DATE menu Activate the SET TIME menu and set the correct time Save the se...

Page 39: ...ore the machine can be used again Check the automatic stop of the machine Start the machine Check if the micro switches are working properly The machine must stop if the door is opened Check the direc...

Page 40: ...h heat Check that the heating is working by opening the door and feel if there is heat in the drum Ready to use If all tests are OK the machine is now ready to be used If some of the tests failed or d...

Page 41: ...ycled and that the refrigerator and heat pump components are special waste assimilable with urban waste The symbol on the product indicates that this product should not be treated as domestic waste bu...

Page 42: ......

Page 43: ......

Page 44: ...Electrolux Professional AB 341 80 Ljungby Sweden Share more of our thinking at www wascomat com...

Reviews: