8.4
Table of pressure and adjustment
Liquied petro-
leum gases
Gas category
Inlet pressure
(mbar)
Nozzle pres-
sure (mbar)
Nozzle size (
⌀
mm)
Air reducing/
restriction plate
(mm)
Label number
May be avail-
able in follow-
ing countries
Butane mixture
/
Propane
mixture
3+
28-30 /
37
No regulation
2.00
490359204
A = 20
490375653
BE, CH, CY,
CZ, ES, FR,
GB, GR, IE, IT,
LT, LU, LV, PT,
SK, SI
Butane
3B/P
30, 37, 50
28
2.00
490359204
A = 20
490375654
BE, CY, DK,
EE, FI, FR, GB,
HU, IT, LT, NL,
NO, SE, SI, SK,
RO, HR, TR,
BG, IS, LU, MT,
PL, AT, CH, DE,
SK
Propane
3P
30, 37, 50
28
2.20
490359204
A = 20
490375655
FI, NL, RO, BE,
CH, CZ, IE, IT,
ES, FR, GR,
GB, HR, LT, NL,
PL, PT, SI, SK,
AT, CH, DE,
NL, LU, SK
A