Installation manual
29
Note!
After connection all joints must be checked. There must not be any leaks.
8.6
Converting instructions
• Disconnect the power to the machine.
• Demount the lower back panel.
• Remove the air reducing plates.
• Remove the nozzle (1).
• Mount the new supplied nozzle.
• Mount the new air reducing plates according to the table.
1
fig.7182
• Loosen the measuring branch screw (2) 1/4 turn; connect a manometer to the measuring branch.
• Connect the power to the machine and select a program with heat.
• Start the machine.
• Set the correct nozzle pressure according to the table on setting screw (4) under the cover screw (3).
2
3, 4
fig.7120
• Check that the gas flame burns evenly.
• Mount the cover screw (3).
• Tighten the screw (2) when the adjustments are done.
• Remount the lower back panel.
Summary of Contents for D7-550
Page 1: ...Installation manual Tumble dryer D7 550 Type N2 Original instructions 438905413 EN 2023 02 27...
Page 2: ......
Page 4: ......
Page 42: ......
Page 43: ......