EXHAUST DIRECTION

EXHAUST DIRECTION

EXHAUST DIRECTION

EXHAUST DIRECTION

EXHAUST DIRECTION
All dryers shipped from the factory are set up for rear exhausting.
However, on electric dryers, exhausting can be to the right or
left side of the cabinet or the bottom of the dryer. On gas dryers,
exhausting can be to the right side of the cabinet or the bottom
of the dryer. Directional exhausting can be accomplished by
installing Exhaust Kit, P/N 131456800, available through your
parts distributor. Follow the instructions supplied with the kit.

EXHAUST DUCT LOCA

EXHAUST DUCT LOCA

EXHAUST DUCT LOCA

EXHAUST DUCT LOCA

EXHAUST DUCT LOCATING DIMENSIONS

TING DIMENSIONS

TING DIMENSIONS

TING DIMENSIONS

TING DIMENSIONS

GAS SUPPL

GAS SUPPL

GAS SUPPL

GAS SUPPL

GAS SUPPLY REQUIREMENTS

Y REQUIREMENTS

Y REQUIREMENTS

Y REQUIREMENTS

Y REQUIREMENTS

 Replace copper connecting pipe that is not

 Replace copper connecting pipe that is not

 Replace copper connecting pipe that is not

 Replace copper connecting pipe that is not

 Replace copper connecting pipe that is not

plastic-coated. Stainless steel or plastic-coated brass MUST

plastic-coated. Stainless steel or plastic-coated brass MUST

plastic-coated. Stainless steel or plastic-coated brass MUST

plastic-coated. Stainless steel or plastic-coated brass MUST

plastic-coated. Stainless steel or plastic-coated brass MUST
be used.

be used.

be used.

be used.

be used.

1. Installation MUST

MUST

MUST

MUST

MUST conform with local codes, or in the absence

of local codes, with the National Fuel Gas Code, ANSI Z223.1
(latest edition).

2. The gas supply line should be of 1/2 inch (1.27 cm) pipe.
3. If codes allow, flexible metal tubing may be used to connect

your dryer to the gas supply line. The tubing MUST

MUST

MUST

MUST

MUST be

constructed of stainless steel or plastic-coated brass.

4. The gas supply line MUST 

MUST 

MUST 

MUST 

MUST have an individual shutoff valve.

5. A 1/8 inch (0.32 cm) N.P.T. plugged tapping, accessible for

test gauge connection, MUST

MUST

MUST

MUST

MUST be installed immediately

upstream of the gas supply connection to the dryer.

6. The dryer MUST

MUST

MUST

MUST

MUST be disconnected from the gas supply piping

system during any pressure testing of the gas supply piping
system at test pressures in excess of 1/2 psig (3.45 kPa).

7. The dryer MUST

MUST

MUST

MUST

MUST be isolated from the gas supply piping

system during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psig (3.45
kPa).

INSTALL MALE FITTINGS IN CORRECT DIRECTION

In installations where the exhaust system is not described in the
charts, the following method must be used to determine if the
exhaust system is acceptable:
1.

Connect an inclined or digital manometer between the
dryer and the point the exhaust connects to the dryer.

2.

Set the dryer timer and temperature to air fluff (cool
down) and start the dryer.

3.

Read the measurement on the manometer.

4.

The system back pressure MUST NOT

MUST NOT

MUST NOT

MUST NOT

MUST NOT be higher than

0.75 inches of water column.  If the system back
pressure is less than 0.75 inches of water column, the
system is acceptable.  If the manometer reading is
higher than 0.75 inches of water column, the system is
too restrictive and the installation is unacceptable.

Although vertical orientation of the exhaust system is
acceptable, certain extenuating circumstances could affect the
performance of the dryer:

Only the rigid metal duct work should be used.

Venting vertical through a roof may expose the exhaust
system to down drafts causing an increase in vent
restriction.

Running the exhaust system through an uninsulated area
may cause condensation and faster accumulation of lint.

Compression or crimping of the exhaust system will cause
an increase in vent restriction.

The exhaust system should be inspected and cleaned a
minimum of every 6 months 

every 6 months 

every 6 months 

every 6 months 

every 6 months with normal usage.  The more

the dryer is used, the more often you should check the
exhaust system and vent hood for proper operation.

CORRECT

CORRECT

CORRECT

CORRECT

CORRECT

INCORRECT

INCORRECT

INCORRECT

INCORRECT

INCORRECT

0

60 ft.

(18.28 m)

     48 ft.(14.63 m)

1

52 ft.

(15.84 m)

     40 ft.(12.19 m)

2

44 ft.

(13.41 m)

     32 ft.  (9.75 m)

3

32 ft.

  (9.75 m)

     24 ft.  (7.31 m)

4

28 ft.

  (8.53 m)

    16 ft.   (4.87 m)

0

30 ft.

 (9.14 m)

     18 ft. (5.49 m)

1

22 ft.

 (6.71 m)

     14 ft. (4.27 m)

2

14 ft.

 (4.27 m)

     10 ft. (3.05 m)

3

          NOT RECOMMENDED

VENT HOOD TYPE

(Preferred)

MAXIMUM LENGTH

of 4” (10.2 cm) Dia. Flexible Metal Duct

Number

 of

90°

 Turns

4”

(10.2 cm)

Louvered

VENT HOOD TYPE

(Preferred)

Number

 of

90°

 Turns

MAXIMUM LENGTH

of 4” (10.2 cm) Dia. Rigid Metal Duct

4”

(10.2 cm)

Louvered

SAME AS OTHER SIDE

SAME AS OTHER SIDE

SAME AS OTHER SIDE

SAME AS OTHER SIDE

SAME AS OTHER SIDE

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

4 3/8"

4 3/8"

4 3/8"

4 3/8"

4 3/8"

(11 cm)

(11 cm)

(11 cm)

(11 cm)

(11 cm)

5 7/8"

5 7/8"

5 7/8"

5 7/8"

5 7/8"

(15 cm)

(15 cm)

(15 cm)

(15 cm)

(15 cm)

13 1/2"

13 1/2"

13 1/2"

13 1/2"

13 1/2"
(34 cm)

(34 cm)

(34 cm)

(34 cm)

(34 cm)

3 3/4"

3 3/4"

3 3/4"

3 3/4"

3 3/4"

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

3 3/4"

3 3/4"

3 3/4"

3 3/4"

3 3/4"

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

(9.5 cm)

(6.35 cm)

2½"

(6.35 cm)

2½"

Summary of Contents for Gas & Electric Gas & Electric Dryer

Page 1: ...hese instructions This will simplify the installation and ensure the dryer is installed cor is installed cor is installed cor is installed cor is installed corr r r r rectly and safely ectly and safely ectly and safely ectly and safely ectly and safely Leave these instr Leave these instr Leave these instr Leave these instr Leave these instructions near the Dr uctions near the Dr uctions near the D...

Page 2: ... exhaust system MUST be exhausted to the outside of dryer exhaust system MUST be exhausted to the outside of dryer exhaust system MUST be exhausted to the outside of the building the building the building the building the building Do not allow combustible materials for example clothing draperies curtains paper to come in contact with exhaust system The dryer MUST NOT MUST NOT MUST NOT MUST NOT MUS...

Page 3: ...l to or less than 1 2 psig 3 45 kPa INSTALL MALE FITTINGS IN CORRECT DIRECTION In installations where the exhaust system is not described in the charts the following method must be used to determine if the exhaust system is acceptable 1 Connect an inclined or digital manometer between the dryer and the point the exhaust connects to the dryer 2 Set the dryer timer and temperature to air fluff cool ...

Page 4: ...OSET DOOR CLOSET DOOR CLOSET DOOR CLOSET DOOR CLOSET DOOR 1 2 54 cm 1 2 54 cm 1 2 54 cm 1 2 54 cm 1 2 54 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 0 0 cm 4 A minimum of 120 square inches 774 2 square cm of opening equally divided at the top and bottom of the door is required Air openings are required to be unobstructed when a door is installed A louvered door with equivalent air openings for the full length ...

Page 5: ...y lay the dryer on its left side and remove foam shipping base To prevent damage do not use the control panel or coin meter housing as a means to pick up or move the dryer NOTE NOTE NOTE NOTE NOTE On under counter model clothes dryers the top panel may be removed for installation 2 Return the dryer to an upright position PACKING FOAM SHIPPING REMOVE 4 SCREWS ONE FROM EACH HINGE FIRST ROUGH IN DIME...

Page 6: ...trical shock Do not use an aluminum wired receptacle with a copper wired power cord and plug or vice versa A chemical reaction occurs between copper and aluminum and can cause electrical shorts The proper wiring and receptacle is a copper wired The proper wiring and receptacle is a copper wired The proper wiring and receptacle is a copper wired The proper wiring and receptacle is a copper wired Th...

Page 7: ...OR 3 WIRE SYSTEM FOR 3 WIRE SYSTEM ELECTRIC ELECTRIC ELECTRIC ELECTRIC ELECTRIC Dryer Dryer Dryer Dryer Dryer 1 Remove the screws securing the terminal block access cover and the strain relief mounting bracket located on the back of the dryer upper corner 2 Install a U L listed strain relief into the power cord entry hole of the mounting bracket Finger tighten the nut only at this time 3 Thread a ...

Page 8: ...aker fuse box Before operating the dryer make sure the dryer area is clear and free from combustible materials gasoline and other flammable vapors Also see that nothing such as boxes clothing etc obstructs the flow of combustion and ventilation air 6 Run the dryer through a cycle check for proper operation NOTE NOTE NOTE NOTE NOTE On gas dryers before the burner will light it is necessary for the ...

Reviews: