- 59 -
Irregular printing
* The printer is in Hex Dump
mode.
* The RS-232 setting is
incorrect.
* Turn off and on the printer to skip the
dump mode.
* Re-set the Rs-232 setting.
Label feeding is not stable
(skew) when printing
* The media guides do not
touch the edge of the media.
* If the label is moving to the right side,
please move the label guide to left.
* If the label is moving to the left side,
please move the label guide to right.
Skip labels when printing
* Label size is not specified
properly.
* Sensor sensitivity is not set
properly.
* The media sensor is covered
with dust.
* Check if label size is setup correctly.
* Calibrate the sensor by Auto Gap or
Manual Gap options.
* Clear the GAP/Black mark sensor by
blower.
Wrinkle Problem
* Printhead pressure is
incorrect.
* Ribbon installation is
incorrect.
* Media installation is incorrect.
* Print density is incorrect.
* Media feeding is incorrect.
* Please set the suitable density to have
good print quality.
* Make sure the label guides touch the
edge of the media guide.
RTC time is incorrect when
reboot the printer
* The battery has run down.
* Check if there is a battery on the main
board.
The printing position of small
label is incorrect
* Media sensor sensitivity is
not set properly.
* Label size is incorrect.
* The parameter Shift Y is
incorrect.
* The vertical offset setting in
the driver is incorrect.
* Calibrate the sensor sensitivity again.
* Set the correct label size and gap size.
* Use DiagTool to fine tune the parameter
of Shift Y.
* If using the software BarTender, please
set the vertical offset in the driver.