background image

Appendix B

32

ASCII TABLE

Use this ASCII Table to add preamble and postamble characters to your
barcode value. Please refer to the appropriate configuration section for the
number of characters that can be configured.

NUL

SOH

STX

ETX

EOT

ENQ

ACK

BEL

BS

HT

LF

VT

FF

CR

SO

SI

DLE

DC1

DC2

DC3

DC4

NAK

CAN

SUB

FS

SYN

EM

ESC

GS

ETB

WCS3900_3905Manual0707_sm.A0  6/25/08  4:32 PM  Page 32

Summary of Contents for CCD Scanner

Page 1: ...0707US Programming Guide Barcode Scanning Made Easy...

Page 2: ...CD Scanner Programming Guide Please Read Note The Wasp WCS3900 Series Scanners are ready to scan the most popular barcodes out of the box This manual should only be used to make changes in the configu...

Page 3: ...stamble Configuration 12 7 Terminator Code ID 13 8 Enable Disable Barcode Symbologies 14 15 9 Barcode Symbology Settings 16 28 Code 39 16 Interleaved 2 of 5 and Code 93 17 Code 128 and UCC EAN 128 18...

Page 4: ...in photodetectors The detectors process the measurement of every bar and space using the number of adjacent photodetectors which contrast a black mark and a white space Wasp WCS3900 Series Scanners a...

Page 5: ...g and tracking and libraries The resolution of a barcode is dependent on the narrowest element of a barcode X dimension and can vary from high density nominally less than 0 009 in 0 23 mm medium densi...

Page 6: ...le directly into your PC s USB port 1 Turn off your computer 2 Unplug your PC keyboard cable and plug the male end Din 6 of the WCS3900 Scanner directly into your PC keyboard port Plug your keyboard c...

Page 7: ...he Setup Configuration sections only to customize the scanners settings Please review the Enable Barcode Symbologies configuration beginning on page 14 to see the list of barcodes symbologies which ar...

Page 8: ...configuration will be maintained even if the keyboard power to the WCS3900 Series Scanners are removed by turning off your PC In order to configure Wasp WCS3900 Series Scanners two basic steps need to...

Page 9: ...WCS3900 Series scanner for the type of host computer Default Keyboard Connection Factory Default Continuous Scan Mode Enable Scan this continuous scan mode barcode to enable continuous scanning This...

Page 10: ...will wait before transmitting the next character If data sent by the scanner has incorrect or missing characters a longer intercharacter delay may solve the problem The intercharacter delay should be...

Page 11: ...Chapter 5 9 BEEP AND DELAY 0ms 10ms 50ms 100ms 200ms 140us 500us 1ms 4ms 16ms 500ms Interblock Delay Intercharacter Delay Default...

Page 12: ...If the scanning performance is poor or cannot scan or the scanner cannot output the upper lower case characters correctly try to select one of the next two choices instead of auto tracing Caps Lock Of...

Page 13: ...Chapter 5 11 KEYBOARD LANGUAGE U S German French Spanish Italian The Keyboard Language setting controls the key codes for your keyboard s language Default...

Page 14: ...ear Pre Postamble barcode on this page 2 Scan the Preamble or Postamble barcode 3 Use Appendix B on pages 32 35 to locate the characters you want to add as preamble or postamble characters Make sure t...

Page 15: ...de ID Code ID On Code ID Off LF CR LF Tab Space ESC The Terminator option is used to specify the end of text message and is primarily used to denote the end of the barcode value The Code ID option sen...

Page 16: ...pter 5 14 ENABLE DISABLE BARCODE SYMBOLOGIES Enable Disable Enable All MSI Plessey Interleaved 2 of 5 Code 128 Codabar Code 39 Disable All MSI Plessey Interleaved 2 of 5 Code 128 Codabar Code 39 Defau...

Page 17: ...Chapter 5 15 ENABLE DISABLE BARCODE SYMBOLOGIES Enable Disable UPC A UPC E EAN 8 EAN 13 Code 93 UPC A UPC E EAN 8 EAN 13 Code 93 Default...

Page 18: ...industrial barcode systems today It is extensively used within the Department of Defense DOD The principal feature is to encode messages using the full alphanumeric character set Standard Code 39 con...

Page 19: ...sed in industrial and master carton labeling and also in the automobile industry The symbology uses bars to represent the first digit of a pair and the interleaved white spaces to represent the second...

Page 20: ...um and maximum lengths To Define UCC EAN 128 Group Separator 1 Scan Define UCC EAN 128 Group Separator 2 Scan ASCII code from pages 31 34 3 Scan Define UCC EAN 128 Group Separator Note Default Group S...

Page 21: ...intervening spaces for each encoded digit one or two symbol check digits and a reverse start code See page 6 for information on setting the minimum and maximum lengths Enable Check Digit Verify And Se...

Page 22: ...e symbologies and is still used in some library applications It should not be considered for new applications except under unusual circumstances See page 6 for information on setting the minimum and m...

Page 23: ...encodes a 12 digit number The first six digits are assigned from the Uniform Code Council UCC The next five digits are assigned by the manufacturer and the final digit is a modulo 10 check digit The n...

Page 24: ...code symbologies 5 Digit Supplement Enable 2 Digit Supplement Enable Transmit if Present 5 Digit Supplement Disable This option expands the UPC A barcode to EAN 13 UPC A to EAN 13 Enable PostScript Pi...

Page 25: ...symbols that have been zero suppressed i e consecutive zeros are not included in the symbol The printed value of the UPC E code is a twelve digit code The nominal height for the UPC E barcode is one i...

Page 26: ...option enables the two and five digit supplements for the UPC and EAN JAN barcode symbologies 5 Digit Supplement Enable 2 Digit Supplement Enable Transmit if Present 5 Digit Supplement Disable 2 Digit...

Page 27: ...PC E code but includes two more digits for the country code The nominal height for the EAN JAN 8 barcode is one inch The reduced size is 80 of the nominal size EAN 8 Enable Send Leading Digit Send Che...

Page 28: ...option enables the two and five digit supplements for the UPC and EAN JAN barcode symbologies 5 Digit Supplement Enable 2 Digit Supplement Enable Transmit if Present 5 Digit Supplement Disable 2 Digit...

Page 29: ...to the UPC A symbology but encodes a 13th digit The nominal height for the EAN JAN 8 barcode is one inch The reduced size is 80 of the nominal size EAN 13 Enable Send Leading Digit Send Check Digit E...

Page 30: ...option enables the two and five digit supplements for the UPC and EAN JAN barcode symbologies 5 Digit Supplement Enable 2 Digit Supplement Enable Transmit if Present 5 Digit Supplement Disable 2 Digi...

Page 31: ...of 5 Codabar Code 128 MSI Plessey Code 93 Note Make sure that the appropriate barcode symbology is configured properly and enabled before trying to scan Use the Barcode Symbologies configuration begi...

Page 32: ...Appendix A 30 BARCODE TEST SYMBOLS UPC A UPC E UPC E w 5 digit supplement UPC E w 2 digit supplement UPC A w 2 digit supplement UPC A w 5 digit supplement Default...

Page 33: ...Appendix A 31 BARCODE TEST SYMBOLS EAN JAN 8 EAN JAN 8 w 5 digit supplement EAN JAN 8 w 2 digit supplement EAN JAN 13 EAN JAN 13 w 2 digit supplement EAN JAN 13 w 5 digit supplement Default...

Page 34: ...and postamble characters to your barcode value Please refer to the appropriate configuration section for the number of characters that can be configured NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF...

Page 35: ...Appendix B 33 ASCII TABLE 0 1 2 3 4 5 6 7 8 9 SP RS US...

Page 36: ...Appendix B 34 ASCII TABLE H I J K L M N O P Q R S T U V W B C D E F G PostScript Picture G eps A X Y _ Z...

Page 37: ...Appendix B 35 ASCII TABLE x y z DEL n o p q r s t u v w a c e g i k m b d f h j l...

Page 38: ...Appendix C 36 FUNCTION CODE FOR PC F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Cursor Right Cursor Left Cursor Up Cursor Down Page Up Page Down Tab Back Tab Esc Enter End Ins Home Back Space Del...

Page 39: ...visible LED Sensor 2088 linear imager Operating Voltage 5 VDC 5 Current Consumption Decoded Standby 30 mA Working 95 mA Output USB or PS 2 MECHANICAL Dimensions L7 40 x W3 62 x H1 06 Weight 125 g with...

Page 40: ...ginal owner and does not extend to any product which has been subject to misuse neglect accidental damage unauthorized repair or tampering No other express warranty is given The replacement or repair...

Page 41: ...on page 7 Q How do I change the terminator to a Tab A Scan the Tab barcode on page 13 Q How do I remove the terminator A Scan the None barcode on page 13 Q How do I enable the Full ASCII character se...

Page 42: ...th the Wasp WCS3900 Series Scanners that you are unable to resolve call for technical assistance at 214 547 4100 ext 2 Monday through Friday 8 00 AM 5 00 PM Central Standard Time Visit www waspbarcode...

Page 43: ...Increases Productivity Profitability Barcode data collection solutions Small business focus Profitable growth since 1986 Over 200 000 customers Business unit of Datalogic SPA Wasp Barcode Technologie...

Page 44: ...Wasp Barcode Technologies 1400 10th Street Plano TX 75074 www waspbarcode com 0707US...