Enter/Exit Programming Mode
PDF417
186
WDI4600
PDF417
PDF417 Enable / Disable
Enables/disables the ability of the reader to decode PDF417 labels.
$CP4EN00(CR)
PDF417 = Disable
$CP4EN01(CR)
PDF417 = Enable
DEFAULT
PDF417 Length Control
This feature specifies either variable length decoding or fixed length decoding for this
symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
$CP4LC00(CR)
PDF417 Length Control = Variable Length
$CP4LC01(CR)
PDF417 Length Control = Fixed Length
Summary of Contents for WDI4600
Page 1: ...WDI4600 1D 2D Digital Scanner USB Product Reference Guide...
Page 10: ...viii WDI4600 NOTES...
Page 14: ...Introduction Programming the Reader 4 WDI4600 NOTES...
Page 24: ...Setup Customizing Configuration Settings 14 WDI4600 NOTES...
Page 28: ...Enter Exit Programming Mode Global Interface Features 18 WDI4600 NOTES...
Page 212: ...Postal Code Selection 202 WDI4600 NOTES...
Page 266: ...Standard Defaults 256 WDI4600 NOTES...
Page 272: ...Keypad 262 WDI4600 A B C D E F...
Page 282: ...Scancode Tables 272 WDI4600 NOTES...