Doc. P/N:
WSP-009-005
Version: V1.5
Issue Date:
October 2013
www.wassp.com
Page 16 of 73
Installation Manual
Note colour code for transmit cable
conductors: White, Black and Green.
5.5.2 Transducer cable Installation
The transducer cable consists of seven CAT-5 cables and one
screened pair for the transmit connection.
To fit the RJ-45 connectors and cable through the gland, no special
preparation is required.
The BTxR cable end has the RJ-45 connectors fitted with “staggered”
cable lengths. This allows each RJ-45 connector and its associated
cable to be fed through the gland fitting easily.
Commencing with the black RJ-45 cable and black transmit cable,
feed each cable in turn through the gland, finishing off with the grey
RJ-45 connector and cable.
Complete fitting and tightening the gland as shown in “Figure 9. Gland
Assembly - Cable Connectors” on page 16.
Figure 9. Gland Assembly - Cable Connectors