9.1.3 Data Collection
You will need to enable HYPACK
®
output from the WMB-3250 GUI. Do this by opening the
Processing Tab
under
Ship Setup
, and ticking the
Enable
checkbox under
Third Party
Output Options
. You will need to select
Hysweep
from the list.
When everything is configured select Survey and HYSWEEP Survey. This will open the
HYPACK
®
survey program and the HYSWEEP Survey interface. The HYPACK
®
side takes care
of position and the HYSWEEP side connects to the WASSP Multibeam to collect Multibeam
data, Attitude and Heave data.
Figure 29. HYPACK
®
Survey
When the system first starts, the Survey window will have to sync to the WASSP data stream,
this could take up to one minute. The HYSWEEP Survey program once connected will update
the Depth, Time, Roll, Heave, Heading, Pitch and Sound Velocity values as they are received
from the WASSP system.
Figure 30. HYSWEEP Data Streams