10.1.6 Commissioning Step 6: Heading (Yaw) Offset
WASSP will operate better with a source of true heading. If magnetic heading is the only
heading available then enter the magnetic deviation into the Heading Offset. The Heading offset
can also be used to correct for alignment problems between the transducer and the heading
source. Refining this offset is a complex process and requires good position accuracy (DGPS or
better).
On the
Menu Task Bar
, click
Ship Setup
Button
In the
Sensor Values
tab, enter a value of 0 if your true heading sensor is correctly aligned, or
enter the heading offset (due to misalignment or magnetic heading if using HDG).
Figure 43.
Heading (Yaw) Configuration Settings