background image

4. ELECTRICAL CONNECTIONS

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of
malfunction or breakdown, grounding provides a path
of least resistance for electric current to reduce the
risk of electric shock.

DANGER: 

Improper connection of the equipment-

grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or service-
man if you are in doubt as to whether the appliance
is properly grounded.

NOTE:  

Disconnect electric power to disposer circuit

before installation. Turn the circuit breaker to the
OFF position or remove the fuse.

A.

Connect disposer to 110-120 Volt, 60 Hz AC 

current only.

GROUNDING INSTRUCTIONS

This appliance must be connected to a grounded,
metal, permanent wiring system; or an equipment-
grounding conductor must be run with the circuit 
conductors and connected to the equipment-grounding
terminal or lead on the appliance.

A.

If you use BX cable:

1. Install cable connector in hole.

2. Connect white wire to white lead of disposer.

3. Connect black.

4. Connect bare ground.

If BX cable is not used, provide a separate ground
wire to nearest cold water metal pipe or other 
suitable ground, using screw in bottom end bell 
for the ground wire (See 4C).

B.  

If your power supply does not include a ground

wire, you must supply one unless metal cable is
used. Attach a copper wire securely to disposer
ground screw and attach other end of wire to a
metal cold water pipe. Use only UL approved
ground clamp. If plastic pipe is used, a qualified
electrician should install a proper ground.

RED RESET
BUTTON

GREEN
GROUND
SCREW

WIRE NUTS

REMOVE
COVER
PLATE

4C

If you are not familiar with electrical power and procedures call a qualified electrician.

For quick and easy reference, record your
Model # and Serial # on the front of this guide.

TO 
CURRENT 

Summary of Contents for WLC-100

Page 1: ...Toll Free Help Line our highly trained technical staff is available to help with any installation or warranty questions you may have We re always here for you 1 800 854 3229 4240 E La Palma Avenue An...

Page 2: ...g electrical appliances basic precautions should always be followed including the following CLEANING MAINTENANCE DO NOT ATTEMPT TO LUBRICATE YOUR DISPOSER The motor is permanently lubricated The dispo...

Page 3: ...m sink flange by turning to the left clockwise see 1B If you are unable to turn ring tap on one of the tubes with a hammer or put a screwdriver through the tube and use it as a lever to turn ring Caut...

Page 4: ...e Before you connect the disposer to the mount assembly under the sink you may want to practice engaging the GROOVE of the Hush Cushion to the RIDGE at the bottom of the sink flange see 3A and read Se...

Page 5: ...h the circuit conductors and connected to the equipment grounding terminal or lead on the appliance A If you use BX cable 1 Install cable connector in hole 2 Connect white wire to white lead of dispos...

Page 6: ...wn the drain go table scraps peelings cobs rinds seeds pits small bones and coffee grounds To speed up food waste disposal cut or break up large bones rinds and cobs Large bones and fibrous husks requ...

Page 7: ...he bottom See 8A Push button in until it clicks and remains depressed If re set button has not been tripped check for shorted or broken wire connecting to disposer Check electrical power switch fuse b...