background image

Installation and  

Placement 

WatchDog loggers have the versatility to be located in any 
micro-climate for recording weather data.  The sensors and 
the mini-radiation shield include hardware for attaching them 
on a 1” to 1¼” outside diameter mast (pipe).  Use a 5’ - 10’ 
length of conduit or pipe as the mast mount.  When 
purchasing and/or cutting the mast to size, plan on placing 
1½’ - 2’ of the mast into the ground.   
 
For outdoor and greenhouse use, the logger should be 
placed in a 3663A Radiation Shield to protect it from solar 
radiation and other sources of reflected heat.  The radiation 
shield also protects the A125 and A130 loggers from rain.  To 
place the WatchDog into the radiation shield, unscrew the 
two finger-nuts and remove the top of the radiation shield.   

 

Important: 

 External sensor wires 

connect to the logger from the side 
at the point where the top and bot-
tom sections meet.  Secure the 
external sensor wires to the mast 
just below the radiation shield with 
a plastic tie to ensure that the 
sensor wires do not become 
disconnected while recording. 

Radiation Shield 

Summary of Contents for A110

Page 1: ...A Series Data Loggers PRODUCT MANUAL Model s A110 A125 A130 and A150...

Page 2: ...6 Battery Replacement 7 Trouble Shooting 7 Warranty 8 Model Specifications 2 Contents Model Internal Sensors External Sensors Measurement Capacity A110 Temp None 8 000 data points A125 Temp Temp 8 000...

Page 3: ...e data logger The jack labeled Ext is reserved for an external sensor if applicable The only time you must have the WatchDog connected to the computer is during the launching and downloading of the da...

Page 4: ...initializa tion screen will open Enter the serial number printed on the back of the logger Logger Models A125 and A130 are physically the same The Model A130 must be electronically marked so SpecWare...

Page 5: ...You may also choose to Delay the start of logging to a later time Downloading The Loggers The download sequence is initiated by selecting the Get WatchDog A Series data option from the Logger menu or...

Page 6: ...the logger should be placed in a 3663A Radiation Shield to protect it from solar radiation and other sources of reflected heat The radiation shield also protects the A125 and A130 loggers from rain T...

Page 7: ...Using an earlier version will result in in valid data Q Can I use the external port of my WatchDog Model A125 or A130 to monitor rainfall or other sensors A No The external port is only set up to be...

Page 8: ...work manship for one year from the date of purchase During the warranty period Spectrum will at its option either repair or replace products that prove to be defective This warranty does not cover dam...

Reviews: