ATEX Beacon
D e t e c t i o n
8
Specifications
Size
20,5 x 13,6 cm
(7.87 x 5.11 in.)
Weight
1675grams (3.69lbs.)
Operating Temperature
-20 to +40°C (-4 to 104°F)
IP Rating
IP 65
Cable entry
2 x ¾”NPT
Material
Copper free aluminium LM6 (copper<0.05%)
With epoxy coating
Operating Voltage
9 – 30V DC
Energy consumption
9W Max (Stand-by <0.1W)
Potential free relay contact
24V DC 2A Max
User Options
Light effect, Colour selection
EX mark
II 2 GD Ex d IIC T6 (INERIS 01ATEX0072x)
Can be used in zone
1, 2, 21 and 22
Meets the standard IEC60079 and EN60079
Troubleshooting
Error
Solution
Beacon will not turn on Check power supply
Check trigger input
Check connection cable from let insert to J3 ensure is connected
Check if trigger jumper is installed correctly
Wrong colour
Check if correct trigger is pulsed
Is there a higher priority trigger active( Blue>Green>Yellow>Red
Beacon runs colour
pattern automatically
Disable demo mode
No response on triggers Check if the beacon is set to analogue mode