Specifications 

Size 

20,5 x 13,6 cm 

(7.87 x 5.11 in.) 

Weight 

1675grams (3.69lbs.)  

Operating Temperature 

-20 to +40°C (-4 to 104°F) 

IP Rating 

IP 65 

Cable entry 

2 x ¾”NPT 

Material 

Copper free aluminium LM6 (copper<0.05%) 

With epoxy coating 

Operating Voltage 

9 – 30V DC  

Energy consumption 

9W Max  (Stand-by <0.1W) 

Potential free relay contact 

24V DC 2A Max 

User Options 

Light effect, Colour selection 

EX mark 

II 2 GD Ex d IIC T6  (INERIS 01ATEX0072x) 

Can be used in zone  

1, 2, 21  and  22

 

Meets the standard IEC60079 and EN60079 

Troubleshooting 

Error 

Solution 

Beacon will not turn on  Check power supply 

Check trigger input 
Check connection cable from let insert to J3 ensure is connected  
Check if trigger jumper is installed correctly 

Wrong colour  

Check if correct trigger is pulsed 

Is there a higher priority trigger active( Blue>Green>Yellow>Red 

Beacon runs colour 

pattern automatically 

Disable demo mode 

No response on triggers  Check if the beacon is set to analogue mode 

 

 

 

Summary of Contents for ATEX BEACON

Page 1: ...D e t e c t i o n Manual Atex Beacon 78 Ultra bright RGB LEDs Colour selectable patterns Partnr ATEX BEACON M A N U A L...

Page 2: ...t the ATEX Beacon 3 PCB layout 4 Installation 5 Analogue controlled 5 Modbus controlled 6 Settings 6 Supported codes 6 Register map 7 Pin numbers 7 Light effect types 7 Specifications 8 Troubleshootin...

Page 3: ...disposal advice as regional variations apply You may return the unit to us for safe dismantling and disposal IMPORTANT This user manual contains important information regarding the operation of the A...

Page 4: ...ut Power supply 9 30V DC min 9W Stand by current 0 1W Trigger voltage positive 6 30V DC Trigger voltage ground min 6V DC below supply Trigger current max 6mA Cable diameter 0 25mm2 to 3 0 mm2 12 to 24...

Page 5: ...ct if you want to use the beacon analogue or controlled by Modbus ANALOGUE CONTROLLED Select the if the trigger is positive or negative trigger by setting the Jumper to the right position Select the m...

Page 6: ...scription DIP switch Modbus ID 0 disabled 1 255 Select Modbus 5 12 adres Baudrate 9600 9600 19200 Baudrate in 2 symbols per second Function Function name Used for code 3 Reading holding register s Rea...

Page 7: ...Light effect types The input status register reflects the value of the input pins Toggling these pins while the unit is configured as a Modbus device does not affect the operating be havior ATEX Beac...

Page 8: ...ct Colour selection EX mark II 2 GD Ex d IIC T6 INERIS 01ATEX0072x Can be used in zone 1 2 21 and 22 Meets the standard IEC60079 and EN60079 Troubleshooting Error Solution Beacon will not turn on Chec...

Page 9: ...0 94 1 0 0 1 1 1 1 0 158 1 1 0 1 1 1 1 0 222 0 0 0 1 1 1 1 1 31 0 1 0 1 1 1 1 1 95 1 0 0 1 1 1 1 1 159 1 1 0 1 1 1 1 1 223 0 0 1 0 0 0 0 0 32 0 1 1 0 0 0 0 0 96 1 0 1 0 0 0 0 0 160 1 1 1 0 0 0 0 0 22...

Reviews: