Hardware Guide
17
Hardware Installation
Precautions
When you install the Firebox in a rack, consider these factors:
Elevated Operating Ambient Temperature
If you install the device in a closed or multi-unit rack assembly, the operating ambient temperature
of the rack environment may be greater than room ambient. Make sure the ambient temperature of
the rack environment is within the certified operating range specified in this Hardware Guide.
Reduced Air Flow
When you install the device in a rack, make sure that the amount of air flow required for safe
operation of the equipment is not compromised.
Mechanical Loading
When you mount the device in the rack, avoid hazardous conditions caused by uneven mechanical
loading.
Circuit Overloading
Make sure you connect the device to the power supply circuit in such a way that there is no
overloading of the circuits, and no impact on overcurrent protection and supply wiring.
Reliable Grounding
Make sure all rack-mounted equipment is correctly grounded. For example, make sure you use power
strips instead of direct connections to the branch circuit.
CAUTION:
Do not use your slide/rail mounted device as a shelf or work space.
Rack Mount Installation Instructions
Separate the inner rails from the outer rails
1. Extend the inner rail until it locks.
2. Press the tab in the inner rail, and pull the inner rail from the outer rail until they completely separate.
After the inner and outer rails are separated, they look like this:
3. Repeat these steps to separate the second inner and outer rail.
Press tab to unlock inner rail
Inner rail