Alarm Definitions
Firebox Vclass User Guide
357
Policy
Select the policy of your choice and then select the
counter you want to use for the alarm. Selecting
For All Policies displays a different list of counters.
System
Select the counter you want to use for the alarm.
VPN End-point Pairs
Select the IPSec pair of your choice and then select
the counter you want to use for the alarm.
6
Click
Select.
For more information about the counters and their capabilities,
see “A Catalog of Real-time Monitor Probe Counters” on
page 368.
The selected conditions appear in the Select Condition dialog box.
7
Select the condition.
8
Delete the text in the <threshold> field, type either a
whole number or a percentage for this counter, and
then click
OK
.
The newly created condition appears in the Counter/Instance list.
9
Repeat this process to define more conditions for this
specific alarm.
As a result, more than one condition will be listed in the Counter/
Instance list