Firebox V10, V60, V60L, V80, and V100 Components
Firebox V10, V60L, V60, V80, V100 Hardware Guide
11
AC Power Cord
Enables you to connect the appliance (using the
supplied power cord) to a 100 to 240VAC (50/
60Hz) power source. The power supply can auto-
detect 110/220 voltage.
Power Supply Switch
Allows you to turn the appliance on or off.
UPS Port
Allows you to use the RS-232 cable provided in the
package to connect the appliance to an
Uninterruptable Power Supply
(UPS). This type of
connection enables UPS devices to notify the
appliance if the power goes out, prompting the
appliance to shut itself down properly.
UPS devices from American Power Company
(APC) are currently supported by the Firebox
Vclass power management firmware. Check the
WatchGuard Web site (
www.watchguard.com
) for
updated information on complete UPS support.
N
OTE
In the event of a power failure, this security appliance, if left
connected to the power source, will automatically restart
itself after electrical power has been restored. You do not
have to press either the Power button on the front or the
power supply switch on the back of the appliance.
Firebox V10, V60, V60L, V80, and V100
Components
Every appliance has three sets of components:
RapidCore™ hardware ensemble
A well-integrated chip set and memory system
powers every Firebox Vclass appliance in its