To install the AP125 on a ceiling with a T-rail:

1. Put the first mounting post on the back of the AP over the lower bracket notch and rotate into place.

2. Make sure that all the mounting posts on the back of the AP are securely positioned in their bracket

notches.

3. To attach the bracket to the T-rail, rotate the bracket so it is parallel to the T-rail, and snap the bracket

on the T-rail.

WatchGuard Technologies, Inc.

9

Summary of Contents for WGA15731

Page 1: ...5 Hardware Guide AP125 Access Point Questo manuale d istruzione fornito da trovaprezzi it Scopri tutte le offerte per WatchGuard AP125 WGA15731 o cerca il tuo prodotto tra le migliori offerte di Wirel...

Page 2: ...y providing best in class Unified Threat Management Next Generation Firewall secure Wi Fi and network intelligence products and services to more than 75 000 customers worldwide The company s mission i...

Page 3: ...Surface Bracket Optional 10 Connect the AP 12 Connect the AP for Link Aggregation 12 Ethernet Power Injector Optional 13 AC Power Adapter 15 Notices 16 Safety Notices 16 Product Safety Certification 1...

Page 4: ...eclaration of Conformity Wireless 20 Brasil ANATEL 23 Mexico NOM 23 Taiwan Class B Notices 23 Taiwan NCC 23 Japan VCCI Notice Class B ITE 23 RoHS Statement 23 WEEE Statement 24 REACH Certificate of Co...

Page 5: ...hat support data rates of up to 876 Mbps and 300 Mbps respectively Requirements There are two ways you can manage your AP125 Total Wi Fi and Secure Wi Fi with WatchGuard Wi Fi Cloud A powerful cloud b...

Page 6: ...n 2 antennas 5GHz radio Ethernet Interface 1 x 10 100 1000 Mbps Gigabit Ethernet LAN2 802 3af PoE 1 x 10 100 1000 Mbps Gigabit Ethernet LAN1 for a wired extension of an SSID or link aggregation Power...

Page 7: ...te clearance for air flow and cooling n Connect it to a surge protected power supply to prevent damage from sudden power changes Other environmental requirements Operating Temperature 0 C to 45 C 32 F...

Page 8: ...on for an SSID or for link aggregation For more information see the WatchGuard Wi Fi Cloud Help For APs managed locally by a Gateway Wireless Controller with Fireware v12 2 1 and higher you can bridge...

Page 9: ...reset button through the hole To reset the device to factory default settings while the AP is powered on press and hold the reset button for up to 10 seconds until all LEDs go off to indicate that the...

Page 10: ...AP Firmware 8 8 1 and Higher LED Status Description Power Off Powered off Solid Green Powered on Flashing Green Not connected to Wi Fi Cloud or paired with a Gateway Wireless Controller No IP address...

Page 11: ...Solid green Powered on LAN1 Off No Ethernet link Solid amber Connected to LAN1 port at 10 100 1000 Mbps Flashing amber Activity on LAN1 port LAN2 PoE Off No Ethernet link Solid green Connected to LAN...

Page 12: ...mounting bracket 15 16 24mm Part WG8027 to install the AP125 on a ceiling with a T rail Optional T rail mount brackets are available from WatchGuard n 9 16 T rail mount 15mm Part WG8026 n Interlude Si...

Page 13: ...the AP over the lower bracket notch and rotate into place 2 Make sure that all the mounting posts on the back of the AP are securely positioned in their bracket notches 3 To attach the bracket to the...

Page 14: ...chGuard Part WG8040 1 Pull the release key outward to unlock the mount bracket 2 Attach the bracket to the mounting surface with screws not included 3 Attach the AP stubs to the bracket holders You ma...

Page 15: ...e Guide 4 Push in the release key to lock the hooks Make sure all hooks are locked in place 5 Use a T10 screwdriver to fasten the included screw to the release key to lock the AP to the bracket WatchG...

Page 16: ...le into the 12V DC power receptacle on the back of the AP125 4 Plug the power adapter into an 100V 240V 50 60 Hz AC power source Connect the AP for Link Aggregation With WatchGuard Wi Fi Cloud you can...

Page 17: ...ard AP 1 Plug the Ethernet Power Injector into an AC power source 2 Connect an Ethernet cable from your network backbone for example a router switch or hub to the LAN connector on the Ethernet Power I...

Page 18: ...ata POE RJ 45 for 10 100 1000 Mbps data and power Voltage Pin4 5 54V Pin7 8 Return Indicator Power Green Temperature Operating 0 40 C 32 104 F Storage 30 80 C 22 176 F Humidity 5 90 Operating and stor...

Page 19: ...US EU UK and AU region specific adapter plugs AC Power Adapter Specs WatchGuard Part Number WG8041 AC Input Voltage Rating 90 264VAC Output Voltage DC 12V 1 5A Region Specific Adapter Plugs US EU UK...

Page 20: ...3 Safety Warning n Do not place objects on the power cord n Do not obstruct the ventilation openings These openings prevent overheating of the machine n Never push objects of any kind into slots or op...

Page 21: ...atentamente las siguientes instrucciones antes de utilizar el producto y se refieren a ellos como sea necesario para garantizar el funcionamiento seguro y continuo de su producto Informaci n adicional...

Page 22: ...the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter For operation within 5 15 5 25GHz 5 47 5 725GHz...

Page 23: ...un fonctionnement ind sirable Caution i the device for operation in the band 5150 5250 MHz is only for indoor use to reduce the potential for harmful interference to co channel mobile satellite system...

Page 24: ...n dynamique de fr quences DFS pour les dispositifs fonctionnant dans les bandes 5250 5350 MHz 5470 5600 MHz et 5650 5725 MHz For indoor use only Pour une utilisation en int rieur uniquement Radiation...

Page 25: ...io spectrum Matters ERM ElectroMagnetic Compatibility EMC standard for radio equipment Part 17 Specific conditions for Broadband Data Transmission Systems This device is a 5GHz wideband transmission s...

Page 26: ...WatchGuard AP125 Hardware Guide 22 WatchGuard Technologies Inc...

Page 27: ...luyendo la que pueda causar su operaci n no deseada Taiwan Class B Notices Taiwan NCC Japan VCCI Notice Class B ITE RoHS Statement The member states of the European Union approved directive 2002 95 EC...

Page 28: ...estriction of Chemicals came into effect on June 1 2007 REACH is Europe s new chemicals legislation which is applicable in all 27 EU Member States as well as the EFTA European Economic Area EEA REACH...

Reviews: