background image

WatchGuard

®

 XCS

Hardware Guide

XCS 280, 580

BL5E4E3

Summary of Contents for XCS 280

Page 1: ...WatchGuard XCS Hardware Guide XCS 280 580 BL5E4E3 ...

Page 2: ...d productivity For more information please call 206 613 6600 or visit www watchguard com Copyright Information Copyright 2013 WatchGuard Technologies Inc All rights reserved WatchGuard the WatchGuard logo LiveSecurity and any other mark listed as a trademark in the Terms of Use portion of the WatchGuard Web site that is used herein are either registered trademarks or trademarks of WatchGuard Techn...

Page 3: ...tegrated threat prevention for viruses spam spyware phishing and malware attacks all in a secured appliance Secure Operating System The WatchGuard XCS delivers the most complete securityavailable for messaging systems The appliance runs on a customized secure operating system that does not allow uncontrolled access to the system There is no command line access and the WatchGuard XCS runs as a clos...

Page 4: ...Power Supply 220W 100 240 VAC 1 2A MAX 50 60 Hz Autosensing Universal Power Supply 220W 100 240 VAC 1 2A MAX 50 60 Hz Autosensing Network Interfaces 3 x Intel 82583V GBe Onboard 3 x Intel 82583V GBe Onboard USB Ports 2 x USB ports 2 x USB ports I O Interfaces 1 x SATA 1 x PS 2 Mouse 1 x PS 2 Keyboard 1 x VGA DB15 1 x Serial DB9 1 x SATA 1 x PS 2 Mouse 1 x PS 2 Keyboard 1 x VGA DB15 1 x Serial DB9 ...

Page 5: ...ch as a locked room to keep the device from people who do not have permission to use it Connect it to a conditioned power supply to prevent damage from sudden power changes Other environmental requirements for the WatchGuard XCS device Operating temperature 0 40 C 32 104 F Non operating temperature 20 70 C 4 158 F Operating and Non operating relative humidity 5 90 Non condensing ...

Page 6: ... supplied to the device and the device is operational Hard Disk Activity The hard disk activity indicator flashes when the disk drive is active Network Interface Activity NIC1 The network interface activity indicators flash when network activity is detected on the first onboard network interface Network Interface Activity NIC2 The network interface activity indicators flash when network activity i...

Page 7: ...l port COM1 to connect a UPS Uninterruptible Power Supply The serial port can also be used to connect to the serial console if you do not have a monitor and a keyboard VGA Video Interface Console You can use the VGA video connector to connect a monitor and view the XCS device console screen AC Receptacle Accepts a detachable AC power cord supplied with the device Power Supply Fan The fans decrease...

Page 8: ...face Indicators Each network interface has a pair of indicators The left indicator is the activity indicator for the interface The right indicator shows the connection speed for the interface Indicator Indicator Color Interface Status Activity Left Not lit No connection Amber Connection established Blinks Network activity data sent and received Connection Speed Right Not lit Operates at 10 Mbps or...

Page 9: ...d Air Flow When you install the XCS device in a rack make sure that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading When you mount the XCS device in the rack avoid hazardous conditions caused by an uneven mechanical load Circuit Overloading Make sure you connect the XCS device to the power supply circuit in such a way that no circuits are o...

Page 10: ...Hardware Specifications 8 ...

Page 11: ... for performance of enforcement of or damages or other relief on account of any such warranties or any breach thereof 2 REMEDIES If any Product does not comply with the WatchGuard warranties set forth in Section 1 above WatchGuard will following receipt of the product you claim is defective and at its option either a repair the Product or b replace the Product provided that you will be responsible...

Page 12: ...ernational Sales of Goods as amended shall not apply You agree not to directly or indirectly transfer the Product or associated documentation to any country to which such transfer would be prohibited by the U S Export laws and regulations If any provision of this Warranty is found to be invalid or unenforceable then the remainder shall have full force and effect and the invalid provision shall be ...

Page 13: ...Hardware Guide 11 Legal and Regulatory Information Declaration of Conformity ...

Page 14: ...cable must be plugged into an approved three contact electrical outlet with the grounding wire connected to an electrical ground safety ground at the power outlet The Lithium Battery used in the security appliance may not be replaced by the user Return the appliance to a WatchGuard authorized service center for replacement with the same or equivalent type recommended by the manufacturer If for any...

Page 15: ... de utilizar el producto y se refieren a ellos como sea necesario para garantizar el funcionamiento seguro y continuo de su producto Certificación de seguridad del producto El producto tiene certificación de seguridad WatchGuard bajo las siguientes normas CAN CSA C22 2 No 60950 1 07 A1 2011 IEC 60950 1 Amd1 2nd Edition 2005 UL 60950 1 2007 R12 11 EN 60950 1 2006 A11 A1 A12 Advertencia de seguridad...

Page 16: ...y to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CE Notice The CE symbol on your WatchGuard Technologies ...

Page 17: ...n de este equipo está sujeta a las siguientes dos condiciones 1 es posible que este equipo o dispositivo no cause interferencia perjudicial y 2 este equipo o dispositivo debe aceptar cualquier interferencia incluyendo la que pueda causar su propia operación no deseada Taiwan Notice Korea Notice ...

Page 18: ...ent The member states of the European Union approved directive 2002 95 EC Restrictions of Hazardous Substances RoHS directive that became valid on July 1 2006 It states that all new electrical and electronic equipment put on the market within the member states must not contain certain hazardous materials The WatchGuard XCS complies with the European Union s R0HS directive 2002 95 EC and similar re...

Page 19: ... policy REACH Registration Evaluation Authorization and restriction of Chemicals came into effect on June 1st 2007 REACH is Europe s new chemicals legislation which is applicable in all 27 EU Member States as well as the EFTA European Economic Area EEA REACH creates a new system for gathering information assessing risks to human health and the environment and authorizing or restricting the marketi...

Page 20: ...Legal and Regulatory Information 18 ...