WaterBoss Softener Two-Button Owner’s Manual 

5/12/2011 

Getting Maximum Efficiency From the Appliance 

To achieve the maximum benefit and performance from 
this appliance, familiarize yourself with this manual and 
the appliance.  

1.

 

The salt level should always be at least 1/3 full. 
Refill the salt when the level drops below the 
water level in the brine cabinet. A resin cleaner can 
be used on a monthly basis. A clean pellet, solar, 
or cube type salt is recommended. Do not use 
rock salt. 

Caution: Do not mix different types of salt.

 

2.

 

You may switch to a salt substitute (such as 
potassium chloride) in place of water conditioner 
salt at any time. If potassium chloride is used in 
place of salt, increase your hardness setting by 
12% (multiply by 1.12). See 

Setting the Controller

.  

Caution: Do not use potassium chloride if your 
water contains iron and/or manganese.

 

3.

 

Should your electricity be off for any reason check 
your controller for the correct time and reset as 
necessary (See 

Advanced Customer Settings

). 

4.

 

Program the appliance to regenerate at a time 
when the water is not being used. If there is more 
than one appliance, allow two hours between 
each regeneration.  

5.

 

Protect the appliance, including the drain line, 
from freezing.  

6.

 

Adhere to all operational, maintenance, and 
placement requirements.  

7.

 

If your appliance runs out of salt: 

A.

 

Open the salt lid and add salt. 

B.

 

Wait two hours, then press and hold the 

R

 button for 5 seconds. 

C.

 

Regeneration is complete after approximately 
12 to 45 minutes, and the appliance is returned 
to Normal Operation. 

8.

 

If dirt, sand, or large particles are present in the 
water supply, the appropriate 

WaterBoss

®

 filter can 

eliminate this problem. 

9.

 

The appliance may be disinfected with 5.25% 
sodium hypochlorite, which is the active ingredient 
in household chlorine bleach. To disinfect the 
appliance, add 4.0 fluid ounces (120 mL) of chlorine 
bleach solution to the brine well of the brine cabinet. 
The brine cabinet should have water in it. Start a 
manual regeneration.  

10.

 

The bypass valve (located on the main control 
valve) enables you to bypass the appliance if any 
work is being performed on the appliance, well 
pump, or plumbing. See 

Bypass Valve

. Use Bypass 

mode also for watering plants or lawns with 
untreated water.  

11.

 

Before putting the appliance back in service after 
work has been performed, turn on the nearest cold 
water tap until water runs clear.  

12.

 

Inspect and clean the brine cabinet and air 
check/draw tube assembly annually or when 
sediment is present in the brine cabinet. 

13.

 

Potassium permanganate will need to be added 
periodically to any iron filter. 

14.

 

This product is certified for barium and radium 
226/228 reduction according to NSF/ANSI 
Standard 44. Any Bypass system must be 
completely in the Service position to ensure 
maximum barium and radium 226/228 reduction. 
 
 
 

Summary of Contents for PRO180

Page 1: ...P PR RO O1 18 80 0 A AN ND D P PR RO OP PL LU US S3 38 80 0 O OW WN NE ER R S S M MA AN NU UA AL L A AN ND D I IN NS ST TA AL LL LA AT TI IO ON N G GU UI ID DE E V VE ER RS SI IO ON N 1 1 0 0 T TW WO O B BU UT TT TO ON N ...

Page 2: ...ling these substances in the system specifications other special treatment of the water supply must be used to remove these substances before they enter this product Otherwise WaterBoss shall have no obligations under this warranty This warranty does not cover damage to a part or parts of the system from causes such as fire accidents freezing or unreasonable use abuse or neglect by the owner This ...

Page 3: ...4 836 9876 Help is also available on the WaterBoss website www waterbosspro com The HelpLine is available to answer questions about specific water problems appliance installation and operation When calling the HelpLine please have this guide and the serial number of your appliance available WaterBoss 4343 S Hamilton Rd Groveport OH 43125 Warning This appliance must be applied to potable water only...

Page 4: ...appliance runs out of salt A Open the salt lid and add salt B Wait two hours then press and hold the R button for 5 seconds C Regeneration is complete after approximately 12 to 45 minutes and the appliance is returned to Normal Operation 8 If dirt sand or large particles are present in the water supply the appropriate WaterBoss filter can eliminate this problem 9 The appliance may be disinfected w...

Page 5: ... for every 1 ppm 1 mg L of ferrous iron Water Characteristics Softeners require a pH of 7 or above to function properly An iron test to determine iron levels is also necessary The 900 NF Acid Neutralizing Filter adjusts pH levels of 6 3 or above Water Hardness Double check hardness of water with test strips provided to verify that your appliance is right for the job Model Pro180 will condition wat...

Page 6: ... outlet of the appliance to the inlet of the water heater Do Not 1 Do not install if checklist items are not satisfactory See Checklist Before Installation 2 Do not install if the incoming or outlet piping water temperature exceeds 120 F 49 C See Specifications 3 Do not allow soldering torch heat to be transferred to valve components or plastic parts when using the optional copper adapters 4 Do no...

Page 7: ...placement area is clean B Turn off the electricity and water supply to the water heater For gas water heaters turn the gas cock to Pilot C Examine the inlet plumbing to ensure that the pipe is not plugged with lime iron or any other substance Clean or replace plugged plumbing Note A pipe with a minimum of 3 4 inch I D is required between the pressure tank and the appliance for the appliance to fun...

Page 8: ...for 3 4 inch copper plumbing or 3 4 inch CTS CPVC plastic tubing Ensure that the three components 1 collar 2 metal retaining ring and 3 nylon sleeve are correctly installed in sequence on the pipe See Figure 2 Note Teflon tape or plumber s putty is NOT necessary and should NOT be used with Qest fittings Figure 2 Qest Fittings D Attach the water lines to the appliance in compliance with all state a...

Page 9: ...e drain line and adapter to 3 4 inch I D The end of the drain line must be equal to or lower in height than the control valve Caution The drain line must not be kinked crimped or restricted in any way Step 6 Flush Lines A Place the appliance in the Bypass position See Figure 6 B Turn on the main water supply C Open the nearest cold water faucet to flush the plumbing of any excess soldering flux ai...

Page 10: ... Step 11 Fill the Brine Cabinet With Salt A Fill the brine cabinet with salt Use clean white pellet or solar salt Do not mix pellet with solar salt Note Always keep the salt level above the water level For convenience completely fill the tank when refilling with salt B After you add salt including adding it after the tank has run out of salt wait two hours for saturated brine before starting any r...

Page 11: ...ter To prevent untreated water from entering the home water should not be used inside the home when the appliance is in Bypass mode Ensure that the appliance is returned to Normal Operation when the appliance is repaired or the use of untreated water is complete by turning the knob to Service To blend hardness back into the water using the bypass turn the knob slightly from the Service position to...

Page 12: ...of soft water remaining until the next automatic regeneration Typically each person in the household uses about 75 gallons 284 L per day Water remaining is in gallons or liters in hundreds For example 5 500 gallons 19 1900 liters Recharge Regeneration Status Shows regeneration cycle numbers during regeneration The display will blink the cycle number The blinking regeneration numbers are First cycl...

Page 13: ...minate iron buildup in the resin bed Salt with an iron cleaning agent or iron out cleaner is recommended for continuous use as a preventive measure against iron fouling of the resin bed Properly using this feature and following these tips will help to ensure a long service life for your appliance Button Function P Used to program and save Customer Settings R Used to change Customer Setting values ...

Page 14: ...General Information on page 3 of this manual C Use the following example to determine the controller setting Your Water English Example Metric Example Enter hardness grains per gallon mg L x 10 20 34 If your water contains 3 ppm mg L iron add 15 26 15 26 The sum is your controller setting number 32 60 Increase your water hardness setting by 5 grains per gallon 8 6 mg L x 10 for every 1 ppm mg L of...

Page 15: ...s per pound 570 grams kg of salt This choice meets or exceeds the requirements some states currently have in regards to salt efficiency 2 S2 will provide more capacity between regenerations than S1 3 SA is the automatic salt setting that uses the average daily water usage to determine an appropriate salt dosage not to exceed the appliance s maximum capacity Note This salt setting is recommended fo...

Page 16: ... setting is displayed press the P button Step 5 Set 96 Hour Mode A The 96H indicator will blink and the display reads indicating the default status of on B Press the R button to cycle between and If the 96 Hour mode is on the 96H indicator is displayed during Normal Operation The 96 Hour mode prevents the appliance from going longer than 4 days without a regeneration Note If there is iron in your ...

Page 17: ...The indicator bar below the digits will blink and the display reads designating the default of English units gallons B Press the R button to cycle between off and on Choosing will set the units to metric liters When metric units are active the indicator bar below the digits is displayed during Normal Operation C When the desired setting is displayed press the P button Step 3 Restore Factory Defaul...

Page 18: ...Cabinet and Assemblies Figure 10 Cabinet and Assemblies WaterBoss Softener Two Button Owner s Manual 5 12 2011 18 ...

Page 19: ...itting 1 2 NPT x Barb 1 36 93223 Injector Throat 1 11 90614 3 0 Drain End Cap Assembly 1 37 53224 Injector Nozzle with Over Mold Gasket 1 12 93835 Sleeve 2 38 93806 O Ring 1 13 90819 O Ring 2 39 53235 Injector Cap 1 14 93530 Media Tank Empty Model Pro180 1 40 53511 Brine Piston Assembly O Ring Spring 1 380210 Media Tank Empty Model ProPlus380 41 90821 O Ring 1 15 93838 O Ring 2 42 53510 Housing 1 ...

Page 20: ...ective transformer Test with volt meter for 12 VAC at control If less than 10 VAC or greater than 14 VAC replace the transformer No read out in display Defective circuit board With 12 VAC present at controller replace the controller Controller not attached properly Make sure the controller is pushed all the way onto the drive end cap Defective magnet disk Replace magnet disk Appliance stays in reg...

Page 21: ...0 3 L min psi bar 15 1 0 14 6 1 0 Maximum flow rate to drain during regeneration backwash gpm L min 3 0 11 4 3 0 11 4 Minimum Maximum Water Pressure psi bar 20 120 1 4 8 3 20 120 1 4 8 3 Minimum water flow required gpm L min 3 0 11 4 3 0 11 4 Controller type 2 Button 2 Button Frequency of regeneration Demand Demand Salt storage lb kg 120 55 170 78 Height in cm 25 5 64 8 33 4 84 8 Footprint in cm 1...

Page 22: ...Notes ...

Page 23: ...Notes ...

Page 24: ...WaterBoss has these third party listings In Business Since 1956 www waterbosspro com 4343 South Hamilton Road Groveport OH 43125 LITHO USA 2011 180380 RV0511HQWI ...

Reviews: