background image

Tested and Certified by NSF International against 

NSF/ANSI Standard 58  for the reduction of the claims 

specified on the Performance Data Sheet. 

R.O. Drinking Water System

Model No. RO35

INSTALLATION, OPERATION 

& SERVICE MANUAL

1900 Prospect Court 

Appleton, WI 54915

Telephone: (920) 682-6823

Fax: (920) 682-7673

Summary of Contents for RO35

Page 1: ...NSF ANSI Standard 58 for the reduction of the claims specified on the Performance Data Sheet R O Drinking Water System Model No RO35 INSTALLATION OPERATION SERVICE MANUAL 1900 Prospect Court Appleton...

Page 2: ...rtains to people with HIV AIDS patients receiving treatment for cancer recipients of organ or bone marrow transplants transplant patients taking immunosuppressive drugs and persons who have congenital...

Page 3: ...supply to prevent excess reject water from going to drain when the unit is not producing water WATER QUALITY MONITOR The optional Water Quality Monitor has been integrated into the faucet base for ins...

Page 4: ...is available to the user as reverse osmosis treated water when the system is operated without a storage tank or when the storage tank is bypassed Efficiency rating means the percentage of the influen...

Page 5: ...he manifold or concrete anchors for hanging on basement wall Additional tubing or tube connectors Plastic wire ties for organizing tubing TYPICAL RO 35 UNDER SINK INSTALLATION DIAGRAM The Water Qualit...

Page 6: ...housing sediment CARBON MODULE BASEMENT FLOOR please note if air gap in faucet is not used in basement installations a proper air gap must be created please check with local plumbing codes see example...

Page 7: ...n area beneath the faucet under the sink for attaching product and drain tubing are considerations A 2 diameter flat surface is required above and below the installation site The thickness of the moun...

Page 8: ...ink Center punch the hole to provide a starting point for the drill Start with a smaller drill as a pilot and then drill a diameter hole to accept the bolt of a 1 Greenlee Hole Punch 1 chassis punch C...

Page 9: ...K 3 8 POLYTUBE TO DRAIN CLAMP BLACK 1 4 POLYTUBE TO DRAIN PORT ON RO SYSTEM BLUE 3 8 POLYTUBE PRODUCT OUTLET 5 Connect the tubing to the Faucet Push the Blue 3 8 Polytube into the 3 8 Quick Connect Fi...

Page 10: ...When you feel the Valve Handle firmly seated in the clockwise direction the copper tube is pierced and the valve is closed 2b To install on hard Steel or Brass Tubing supply line The supply line shoul...

Page 11: ...filter changes Mark the two locations the bracket can be used as a template Install the screws and tighten them until the heads are about 5 8 from the wall RED BLACK YELLOW IN DRAIN OUT DRAIN RESTRIC...

Page 12: ...rds the manifold Take the remaining housing and insert housing O ring into its groove Engage and firmly tighten housing hand tight only Remove the plug labeled ACTIVATED CARBON from the underside of t...

Page 13: ...rval for changing the modules not the R O Membrane is every 6 to 12 months Typical T F C Membrane life expectancy is three years Local conditions may dictate more frequent changes NOTE If the R O Memb...

Page 14: ...tube out of the fitting 4 Firmly reconnect the polytubes to the new Post Filter Refer to Fig 5 5 Slowly open the Feed Water Saddle Valve 6 When water begins dripping out of the Faucet in the following...

Page 15: ...15...

Page 16: ...e check The ASO Valve is malfunctioning Replace ASO Valve components Low pressure at the Dispensing Faucet In Line Activated Carbon Post Filter is plugged Replace Post Filter Air precharge in the Hold...

Page 17: ...mbing Dissolved gasses in the Feed Water Pretreat Feed Water to remove dissolved gasses Increase in Product Water TDS See high TDS in the Product Water section Drain Water overflows at the Dispensing...

Page 18: ...18 MADE IN USA Exploded View Parts List 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 19 18 15 16 21 Nitrate Nitrite Test Kit 22 Water Quality Test Kit for systems without the Water Quality Monitor...

Page 19: ...ing 14 S3010 Housing 15 R7078 Optional Water Quality Monitor w Probes and Cover 16 S2116 5 Drain Restrictor 50 GPD 189 lpd 17 S7125X Activated Carbon Module 18 S1405 1 4 3 8 Fitting Wrench 19 S3072 Wr...

Page 20: ...ges to return the defective part s What Does This Warranty Not Cover This warranty does not cover the disposable sediment and carbon filters whose service life depends on feed water conditions In addi...

Reviews: