7
Maintenance / Warranty Information
Minimum maintenance requirements:
Given the critical nature of the iron filtration process in protecting assets from destructive
iron staining, we recommend the following minimum maintenance schedule. Failure to per-
form this maintenance could result in performance failures.
Monthly during irrigation season:
1.
Perform flow accuracy test as outlined on page 4.
Annually or before each seasonal activation:
1.
Perform flow accuracy test as outlined on page 4.
2.
Perform inspection and cleaning process on all solenoid valves on manifold. Visit
www.watercontrolinc.com technical video library for details on the cleaning process.
TurfMaster Winterization Procedure:
The TurfMaster irrigation iron filtration system should always be kept from freezing conditions.
Before closing off water supply for irrigation system winterization, it is important to
“
clean
”
the
TurfMaster filter media of residual iron. This can be done by completing a manual regeneration
cycle immediately before closing off supply water. Referring to Illustration 6, press and hold
the
“
Extra Cycle
”
button for 5 seconds. When the panel begins to flash
“
BW
---
“
the unit has
entered a regeneration cycle. When this cycle is complete, and the unit indicates
“
service
”
on
the display, the media will have been cleaned and is ready to standby for a prolonged period of
time.
All BrassMaster and BrassMaster Plus water softeners /
filters feature the Assured Performance Modular (APM)
design. If you experience a failure of any valve component,
the brass module can be easily removed and replaced with a
factory remanufactured replacement module.
Reference the BrassMaster and BrassMaster Plus Technical
Video Library on our website (link is provided below) for
detailed steps on how to remove the module. The required
(downloadable) form to have your module repaired/replaced
is also located at this site.
Please contact your dealer or Water Control Corporation for
module support.
Nearly all serviceable
parts lie within the
removable/replaceable
APM module. This
eliminates costly
and time consuming
field repairs.
BrassMaster and BrassMaster Plus Technical Video Library:
http://watercontrolinc.com/residential
-
technical
-
support/residential
-
technical
-
videos
BrassMaster technical videos show how to set up or remove the control module. If returning your control
module to be repaired/replaced, please use the (downloadable)
Remanufactured Module Order Form
.
For factory module support contact:
Water Control Corporation
●
7150 143
rd
Ave NW
●
Ramsey, MN 55303
Phone: 1
-
866
-
405
-
1268
●
Fax: 763
-
427
-
5665
●