8
Factory Setup of Blastersoft
Blastersoft setup of valve:
1) Fill cycle
9.5 lbs. of salt
2) Softening
120 minutes
3) Backwash cycle
10 Minutes
4) Brine cycle
60 minutes
5) Rinse cycle 4 minutes
6) Ozone draw cycle
30 minutes
Setting the relay:
On time
First relay at:
75 minutes
Second relay (Off): 28 minutes
DAY OVERRIDE IS SET FOR 3 DAYS
Reminder:
The unit must go off every 3
rd
day if you want to remove Sulphur and Iron etc. You can
custom change anything you want but make sure the relay does not come on during the
Rinse Cycle or it will shut off the Ozone unit. Always add a few more minutes to the time
before Ozone and shorten the time on the second relay etc. to keep from water entering
the ozone unit or shutting off prematurely.
Black wire = COM+
Red wire = RLY
REVISED: JUNE 2015