wd-15

Service flow rate 1”

27 gpm (102.2 lpm) @ 15 psig (103 kPa) drop

Backwash flow rate 1” (includes bypass)

27 gpm (102.2 lpm) @ 25 psig (172) kPa) drop

Service Flow Rate 1.25” (includes meter)

34 gpm (128.7 lpm) @15 psig (103 kPa) drop

Service Flow Rate 1.25” (includes meter & bypass)

32 gpm (121.1lpm) @ 15 psig (103 kPa) drop

Backwash flow rate 1.25”

32 gpm (121.1 lpm) @25 psig (172 kPa) drop

Backwash flow rate 1.25” (includes bypass)

30 gpm 9113.5 lpm) @ 25 psig 9172 kPa) drop

Minimum/Maximum Operating Pressures

20 psi (138 kPa) - 125 psi (862 kPa)

Minimum/Maximum Operating Temperatures

40°F (4°C) - 110°F (43°C)

AC Adapter:
Supply Voltage
Supply Frequency
Output Voltage
Output Current

U.S.                               INTERNATIONAL
120 V AC                      230 V AC
60 Hz                            50 Hz
12 V AC                        12 V AC
500 mA                         500 mA

Regenerant Refill Rate

0.5 gpm (1.9 lpm)

Injectors

See Injector Graphs

Drain Line Flow Controls

See Table 7

Inlet/outlet Fitting Options

(a) 1” NPT elbow which has a unique drill out 
feature to allow a 1/4” NPT connection to the 
inlet and/or outlet 
(b) 3/4” &1” PVC solvent weld fitting
(c) 1” straight brass sweat fitting
(d) 3/4” straight brass sweat fitting
(e)  1” plastic male  NPT fitting
(f) 1 1/4” plastic male NPT fitting
(g) 1” plastic make BSPT fitting
(h) 1 1/4” plastic make BSPT fitting

Distributor Tube Opening WS1HR&HS Valve

1.05” outside diameter (3/4” NPS)

Distributor Tube Opening WS1.25HR&HS Valve

1.32” outside diameter (3/4” NPS)
32 mm outside diameter

Tank Thread

2 1/2” - 8 NPSM

Control Valve Weight

4.5 lbs.    2.0 kg

PC Board Memory

Nonvolatile EEPROM
(electrically erasable programmable ready only 
memory)

Compatible with regenerants/chemicals

Sodium chloride, potassium chloride, potassium 
permanganate, sodium bisulfite, chlorine and 
chloramines.

Summary of Contents for Platinum WD SP35BFJCT

Page 1: ......

Page 2: ...wd 2 ...

Page 3: ......

Page 4: ...wd 4 ...

Page 5: ...wd 5 ...

Page 6: ...wd 6 ...

Page 7: ...wd 7 ...

Page 8: ...wd 8 ...

Page 9: ...wd 9 ...

Page 10: ...wd 10 ...

Page 11: ...wd 11 ...

Page 12: ...wd 12 ...

Page 13: ...wd 13 ...

Page 14: ...REFERENCE SPECIFICATIONS CLASSIFICATION Demand initiated regeneration metered OPERATING PRESSURE 20 100 psi 1 4 7 0 kg cm2 OPERATING TEMPERATURE 35 100 F0 1 370 C VALVE SIZE 1 BYPASS VALVE 3 4 OR 1 NPT BRINE TANK DIMENSIONS 14 X 14 REGENERATION Downflow ELECTRICAL SPECIFICATIONS Controller Operating Voltage 12 VAC Input Supply Frequency 60hz Motor Input Voltage 12 VAC Electronic Operating Voltage ...

Page 15: ...generant Refill Rate 0 5 gpm 1 9 lpm Injectors See Injector Graphs Drain Line Flow Controls See Table 7 Inlet outlet Fitting Options a 1 NPT elbow which has a unique drill out feature to allow a 1 4 NPT connection to the inlet and or outlet b 3 4 1 PVC solvent weld fitting c 1 straight brass sweat fitting d 3 4 straight brass sweat fitting e 1 plastic male NPT fitting f 1 1 4 plastic male NPT fitt...

Page 16: ...ect time of day b Time of day not set correctly b Reset to correct time of day c Time of regeneration c Reset regeneration time d Control valve set at on 0 immediate regeneration d Check control valve set up procedure regeneration time option e Control valve set at NORMAL on 0 e Check control valve set up procedure regeneration time option 5 ERROR followed by code number ERROR code 1001 Unable to ...

Page 17: ...en piston retainer f Replace drive cap assembly g Broken main regenerant g Replace main regenerant piston 7 Control valve does not regenerate automatically when REGEN button is depressed and held a AC Adapter unplugged a Connect AC adapter b No electric power at outlet b Repair outlet or use working outlet c Broken drive gear or drive cap assembly c Replace drive gear or drive cap assembly d Defec...

Page 18: ...wd 18 ...

Page 19: ...wd 19 ...

Page 20: ...wd 20 ...

Page 21: ......

Reviews: