Drain Water Line:

 Run up to 50 feet of 3/8" tubing (1/2" tubing if longer than 50 feet) from the DRAIN connection 

of the

 SteamerGard™

 unit to the nearest drain. The

 SteamerGard™

 system has a pressurized drain and 

therefore. the drain Tubing may be run up to 10 feet above the 

SteamerGard™

 unit. The drain termination 

must

 

vent freely to the air, with a proper air gap between the tubing termination and the drain opening, in order to 
comply with local plumbing codes. 

6.   

Purified Water Line to the Storage Tank and Control Panel:

 Run 3/8" tubing from the STORAGE connection on 

the

 SteamerGard™

 unit to one side of the brass tee on the storage tank- Run up to 50 feet of 38" tubing 

 (1/2" tubing if longer than 50 feet) from the other side of the brass tee to the 

SteamerGard™

   connection on the 

control panel, mounted near the steamer. 

7.

    

Purified Water Line to the Steamer:

 Run 3/8" polybutylene tubing from the center connection on the control panel 

to the 

steam generator (boiler)

 connection on the steamer, (not 

the condenser water connection).

 For correct 

connection of this line, consult the steamer manufacturer. 

IMPORTANT:

 When feeding the steamer with purified water from the

 SteamerGard™ 

system, it is

 

imperative

 that the steamer be fitted with two separate water connections; one for purified water to the 

steam generator and a separate one for tap water to the condenser system. If the

 SteamerGard™

 

system is feeding purified water to a steamer that is equipped with only one feed water connection, 
which internally branches off to both the steam generator (boiler) and the condenser system, the steamer 
absolutely 

must

 be altered for use with the

 SteamerGard™

 system.  Consult the steamer manufacturer 

for alteration instructions to convert the steamer from a single feed water connection to two separate 
water connections; one for purified water to the steam generator and a separate one for tap water to the 
condenser system8.

 

Cold Tap Water Line to the Control Panel:

 In accordance with accepted plumbing 

methods, the control panel should be plumbed from an existing cold tap water supply (near the steamer) 
using a lee and a shut-off valve. Run 3/8" tubing from this valve to the 3/8" MANUAL BYPASS 
compression fitting on the control panel. 

9. 

    

Start-Up Procedure:

   Open the cold tap water valve at the main water supply, then open the feed water valve on 

the

 SteamerGard™

 unit. Inspect the feed water plumbing and filters for leaks and correct as necessary. Open the 

valve on the storage tank(s) and inspect plumbing for le aks. Remove the cover from the

 SteamerGard™

 unit, 

exposing the controls, valves, pump and pump pressure gauge. Making sure the power switch is "off ", plug the 
power cord into a 115VAC electrical outlet. Open the FLUSH VALVE so the handle is parallel to the valve body. 
Push the toggle switch for at least 30 seconds to purge the system of air. Turn the handle on the BACK FLOW 
REGULATOR counterclockwise until it just

 

begins to feel loose. Check the TANK PRESSURE gauge on the 

control panel near the steamer. It should read less than 50 psi (0 psi if tank was not pre-filled). Turn the power 
switch to the "on" position. The red light and the pump motor will come on immediately. NOTE: If air has not beer 
completely purged from the filters, the pump motor may cycle on and off several times due to a low pressure 
condition.  Allow the

 SteamerGard™

 unit to run for approximately one minute, then slowly close the FLUSH 

VALVE so its handle is perpendicular to the valve body. Observe the pump pressure gauge. It should read less 
than 100 psi.  Slowly turn the BACK FLOW REGULATOR clockwise to increase the pressure to approximately 
180 psi (the normal operating pressure). System is now in operation and will continue until the tank fills to a 
pressure of 50-60 psi when it will automatically shut off. The system is completely automatic so the power switch 
should always remain in the "on" postion. 

NOTE:

 The steamer must be operated for some time in order to clear the tap water out of the

  

SteamerGard™

 system. Pushing the WATER QUALITY button before all tap water is cleared from 

the system will result in a glowing red light. 

The SteamerGard

 system is now in operation,                    

and the steamer can be used with purified water. 

 

              SteamerGard is a trademark of The Water Factory. Costa Mesa. California 92626 

1987 Water Factory Systems. Costa Mesa. CA                12-7062/7064-CRC 

3

 

Summary of Contents for SteamerGard WT-400

Page 1: ...East 179th St Cleveland Ohio 44110 Phone 216 481 4900 Telex 98 0546 FAX 216 481 3782 Toll Free 1 800 338 2204 in U S A only CANADA 8251 Kelle St Concord Ontario Canada L4K 1Z1 Phone 416 660 4747 FAX...

Page 2: ...Operation 6 Unit 6 Low Pressure Switch 6 SteamerGard Controls and Monitors 6 Power and Depressurize Switch 6 Flush Valve 6 Pump Pressure Control 6 Pump Pressure Gauge 7 Control Panel 7 Control Panel...

Page 3: ...tubing is recommended for plumbing Important Storage tank air precharge should be 12 psi with no water THE CONTROL PANEL is designed to give the operator important information about the status and per...

Page 4: ...ld water supply Carefully holding the control panel against the wall mark the four mounting hole locations that will provide a level installation Drill four holes at the marks for mounting the panel S...

Page 5: ...supply near the steamer using a lee and a shut off valve Run 3 8 tubing from this valve to the 3 8 MANUAL BYPASS compression fitting on the control panel 9 Start Up Procedure Open the cold tap water...

Page 6: ...SteamerGard Model WT 200 WT 400 Typical Installation Schematic 4...

Page 7: ...SteamerGard Models WT 200 WT 400 Component Illustration 5...

Page 8: ...If this condition is observed the SteamerGard unit should be turned off immediately and corrective actions taken Consult your factory representative for preventive measures that will minimize the prob...

Page 9: ...ed tap water to the steamer until repairs can be made To use the manual bypass valve turn the handle fully clockwise so that the handle points to the bypass position Once necessary repairs are made th...

Page 10: ...re attained after the steamer has been in use for a while This ensures that the SteamerGard system has been in operation producing purified water 2 Flush the membrane clean for 5 minutes while the sys...

Page 11: ...torted Screw the filter bowl onto the fitter head by hand NOTE If the SteamerGard system is supplied with water high in sediment content the prefilter may need to be replaced more often than every thr...

Reviews: